6.5.6 Feed History
This screen shows the estimated
daily amount of feed used and the
total time that the feed line motors
have been running.
(1) Day – The specific day in the
growout period. Values =
1 to 99 days.
(2) Usage – The amount of feed
used from Bin #1 and Bin
#2 combined for each day
of growout. Measurements
= pounds (lb.).
(3) Run 1 – The total amount of run-time feed line #1 was running for each day of growout.
Measurements = Hours and minutes.
(4) Run 2 – The total amount of run-time feed line #2 was running for each day of growout.
Measurements = Hours and minutes.
(5) Status – The status of the auger current sensor whether the sensor is On or Off. ON indicates the
motor is running and OFF indicates the motor is not running.
6.6 Alarm Status – MAIN SYSTEM
The ALARM column lists the elements and sensors that are available. For the High and Low temperatures
and High and Low pressure, the Cycle Pressure the current Alarm Limits are shown. For all entries the
STATUS and the LAST REPORTED alarm are indicated. To change the ALARM LIMIT use the Editor
arrows to highlight the desired entry and the Plus (+) and Minus (-) buttons to increase or decrease the
desired limit.
(1)Day (2)Usage (3)Auger1 (4)Auger2
(5)Status On On
41 2100 lb 4:10 9:10
40 2000 lb 3:00 8:00
. . . .
35 1500 lb 3:00 8:00
. . . .
. . . .
24 1000 lb 1:30 6:30
. . . .
. . . .
1 150 lb 1:10 6:10
NOTE: The High and Low
temperature reading is taken from
the Sensors for Display in "Sensor
Setup" of the Program Setup Screen.
Proceed
to Detail
Screens
"
TEMPERATURE LIMIT STATUS LAST ALARM
(1)High Temp 85.0
° OK 08/15-10:36p
(2)Low Temp 65.0
° OK 08/10-03:36p
PRESSURE LIMIT STATUS LAST ALARM
(3)Cycle Press 0.04 Off 08/09-07:36p
(4)High Press 0.15 Off 07/22-01:36p
(5)Low Press 0.03 Off 07/13-06:36p
WATER ALARMS LIMIT STATUS LAST ALARM
(6)High Rate #1 100/hr OK 01/01-12:00a
(7)Low Rate #1 25/hr OFF 01/01-12:00a
(6)High Rate #2 100/hr OK 01/01-12:00a
(7)Low Rate #2 25/hr OFF 01/01-12:00a
FEED ALARMS LIMIT STATUS LAST ALARM
(8)Auger Run1 10min OFF 01/01-12:00a
(9)Auger Run2 10min OFF 01/01-12:00a
SYSTEM STATUS STATUS LAST ERROR
(10)Tunnel Vent ---- OK 07/12-02:36p
(11)Growout Day ---- OK 07/31-05:36p
(12)Local Network ---- OK 07/27-05:36p
(13)Back-Up Limits ---- OK 07/31-05:36p
(14)Sensor 1 ---- OK 07/27-05:36p
(14)Sensor 2 ---- OK 06/10-09:36p
(14)Sensor 3 ---- OK 06/11-01:36p
(14)Sensor 4 ---- OK 06/13-06:36p
(14)Sensor 5 ---- OK 06/13-03:36p
(14)Sensor 6 ---- OK 06/21-03:36p
(14)Sensor 7 ---- OK 06/17-02:36p
(14)Sensor 8 ---- OK 06/13-10:36p
(15)Outside ---- OK 07/13-02:31p