Triple Pole 16-Stage Contactor Panel Hired Hand Mfg., Inc.
Table of Contents Section Title Page 1. Ratings and Specifications .............................................................................................................................1 2. Warnings ........................................................................................................................................................1 3. Limited Warranty ....................................................................................................................................
1. Ratings and Specifications • • • • • Enclosure: 16” x 42” Galvanized Coil Voltage: 230 VAC 50/60 Hz Contact Rating: 0.5 HP @ 1 Phase 115 VAC 1.5 HP @ 1 Phase 230 VAC 2.0 HP @ 3 Phase 200 VAC 2. Warnings Warning! When this equipment is used in a life support heating and ventilation system where failure could result in loss or injury, the user should provide adequate back-up, or accept the risk of such loss or injury! 3.
. Overview The Triple Pole 16-Stage Contactor Panel is designed to interface between a Farm Hand controller and 3 phase load equipment, however in some cases single phase loads may be used. Overloads (thermal relays) are optional equipment for three phase loads which can be used to disconnect the power feed between the contactor and the load whenever a preset load condition occurs (See Section 5). Contactors (16 total) Three Phase 16 Stage Contactor Panel 5.
8. Connecting Overload to a Contactor Overloads can easily be attached to a contactor by: (1) First disconnect all electrical power leading to the contactor. (2) Using a Phillips head screwdriver, unscrew the five terminal screws on the right of the contactor. These are labeled (2T1, 4T2, 6T3, 14NO and A2). (3) Carefully place the overload unit so the five pins align with the contactor as shown below. (4) Press the overload into the contactor until a “snap” is heard.
A2 1410 6 T3 4 T2 2 T1 A1 5 L3 3 L2 L2 L1 13 Connecting Single Stage Equipment – No Overload 1 L1 9.2 OR L2 L1 Contactor A2 Connecting Three Phase Equipment – No Overload 13 1410 A1 9.3 T2 L2 4 T2 1 L1 L1 L1 2 T1 3 L2 L2 L3 6 T3 5 L3 L3 Contactor Connecting Three Phase Equipment – With Overload 97 4 T2 2 T1 98 95 6 T3 96 2.6 1.8 RESET 2.2 A2 1410 A T1 95 T1 98 97 L1 96 LR2K T2 L1 T2 H L2 6 T3 5 L3 Contactor Part No.
10. Parts List Part Number 6604-9000 3015-2892 3015-2893 3015-2895 3015-2896 3015-2897 Part No. 4801-5321 Description Relay Panel 16 Stage Relay Thermal Overload 4.8 Amp 1 HP @ 220V Relay Thermal Overload 2.4 Amp 1 HP @ 440V Relay Thermal Overload 2.6 – 3.7 Amp ½ HP @ 220V Relay Thermal Overload 5.5 – 8 Amp 1½ HP @ 220V Relay Thermal Overload 8 – 11.