Owner manual
Part No. 4801-0062 rev 7-05
  Super Saver Bunsen Jet  Page 15 of 18 
11.  Replacement Parts (120V & 240V models) 
Ref. No.  Part No.  Description 
1  3002-3000  IGNITER mini 120V BJ-32/42-HIS 
7  1901-3061  FLAME SENSOR probe assembly BJ-32/42-HIS (120V model) 
7  1901-3089  FLAME SENSOR probe assembly (240V model) 
14  0015-0100  CERAMIC cast radiant BJ-32/42 
21  6410-0105  Burner orifice assembly 0-2000 ft BJ-32-LP 
21  6410-0106  Burner orifice assembly 0-2000 ft BJ-32-NG 
21  6410-0108  Burner orifice assembly 0-2000 ft BJ-42-LP 
21  6410-0109  Burner orifice assembly 0-2000 ft BJ-42-NG 
25  0404-7554  Burner Heat Shield 
Not Shown  3010-1883  FUSE 5 AMP ¼”X1-1/4” fast acting 
Not Shown  1042-2693  FUSE_HOLDER shock safe 
Not Shown  3004-0104  GAS_VALVE White Rodgers 120 VAC LP BJ-32/42-HIS 
Not Shown  3004-0105  GAS_VALVE White Rodgers 120 VAC NG/LP BJ-32/42-HIS 
Not Shown  6410-0115  Brooder HIS120V Module 
Not Shown  3001-2862  SWITCH SPST toggle tabs 
Wiring Diag.  3008-2858   Transformer 230V to 115V (240V model) 
12. Troubleshooting Guide 
Symptom  Possible Cause  Solution 
Main burner will not 
ignite. 
Thermostat may not be set 
properly. 
Set thermostat to desired house 
temperature. 
The burner venturi may be 
restricted. 
Clean burner venturi to remove 
obstruction. 
Igniter may not reach into 
the path from the burner. 
Make sure the manifold gas pressure is set 
to manufacturer’s recommended pressure. 
If not, adjust to recommended pressure. 
Faulty gas valve.  Replace gas valve. 
Main burner will 
flashback. 
Gas pressure is set 
incorrectly. 
Adjust manifold gas pressure to 
manufacturer’s recommended pressure. 
The orifice may be 
misaligned. 
Adjust orifice so that it is positioned 
perfectly vertical. 
Igniter does not glow. 
Igniter may be 
disconnected. 
Check that wires are connected both at the 
ends of the white wires, and at the control 
enclosure terminal block 
Thermostat preventing 
operation. 
Make sure that your thermostat is set to 
allow the brooder to operate at the present 
temperature. 
Igniter will glow, but 
gas valve will not 
engage. 
Low gas pressure at gas 
valve. 
Check gas supply from line to gas valve to 
be sure that all valves are open, and that 
the regulator is functioning properly. 
Clogged gas orifice.  Check that nothing obstructs the flow of 
gas from the orifice. 
Burner is plugged.  Check that the burner is clear and free 
from obstructions. 
Brooder will light, 
Low gas supply.  Check gas supply. 
but then go out. 
Thermostat too close to 
brooder 
Move thermostat farther away from 
brooder to prevent rapid heating of 