Datasheet
5
Advanced functionality that’s as easy to use as it is easy to understand
Measurement jacks with guard jack
By connecting a probe to the guard jack, you can minimize the
effects of external noise on measurements.
LED COMPARATOR ATTACHMENT (Option)
The LED Comparator Attachment indicates judgment results
with green and red LEDs, eliminating the need to look at the
instrument’s screen and increasing work efficiency. Since the
lamps do not light up when the measurement leads are open, the
attachment can also be used to verify the connection status.
Loud, user-selectable judgment tones
High-volume judgment tones of at least 85 dB inform the
operator of test results, ensuring that they remain audible
even in the vicinity of noisy machinery. The ability to
choose from various tones ensures operators won’t confuse
judgment results on lines where multiple RM3544 units are
in use.
Simple control over basic settings
Range and measurement speed can be controlled directly.
Red light
HI/LO state
Green light
IN state
Material- and temperature-independent temperature
correction function
The temperature correction function can be used to convert resistance values that vary with
the ambient temperature to a reference value at a reference temperature using the Temperature
Sensor Z2001 and a user-specified resistance temperature coefficient.
Panel save and load functionality for
up to 10 sets of parameters
Panel save and load functionality provides the ability to save
and subsequently load up to 10 sets of instrument setting
conditions for range, comparator, and other parameters.
Naming each set of panel data lets you make setup changes
among production lots and lines smoothly and effortlessly.
Comparator Function
The comparator function compares measured values to a
previously set reference value or range and then displays
and outputs the judgment result. The RM3544-01 can also
output comparator results via its EXT I/O interface.
Intuitive, graphical LCD
Scaling
The scaling function can be used to convert
resistance values into physical properties such as
length.
Conversion formula : Rs = A × R + B
A, B : Constants, R : Measurement value
Rs : Resistance value
Material- and temperature-independent temperature
correction function
The temperature correction function can be used to convert resistance values that vary with
the ambient temperature to a reference value at a reference temperature using the Temperature
Sensor Z2001 and a user-specified resistance temperature coefficient.
Panel save and load functionality for
up to 10 sets of parameters
Panel save and load functionality provides the ability to save
and subsequently load up to 10 sets of instrument setting
conditions for range, comparator, and other parameters.
Naming each set of panel data lets you make setup changes
among production lots and lines smoothly and effortlessly.