MEMORY HiCORDER MR8875 Recorders Smart Design - Smart Engineering n n n Tough Against Vibrations and Extreme Temperatures Strengthened body ideal for in-vehicle testing and road tests Compliant with the JIS D 1601: 1995 Vibration Testing Methods for Automobile Parts, 5.
Ideal for Automotive and Transportation Equipment Applications Road test data (analog waveform and CAN data) Construction machinery and heavy equipment development (analog waveform and CAN data) Railway failure analysis (railway test run) Power line quality recording (using the differential probe and clamp probe)
Real-Time Saving to SD Card in High Resolution CAN Signal Measurement for Vehicle Testing Multi-Channel Mixed Measurement of Various Signals Touch Screen for Direct Operation Analyze Data with a Variety of Intelligent Functions
1 Real-Time Saving to SD Card in High Resolution rate with a high resolution of 25,000 point f.s. The same working principle as that of a digital oscilloscope is used to Input A/D conversion Isolation 25,000 point Collect physical signals at a 500kS/s sampling record data to the large-capacity internal memory at high speed. The sampling rate is 500 kS/s (2 μs period) on all channels simultaneously. Sensor signal waveforms are recorded and represented faithfully.
2 CAN Measurement for Vehicle Testing Synchronized mixed recording of CAN data and real data such as voltage, temperature, or distortion signals CAN bus signals that are used widely, particularly in automotive applications, can be recorded, analyzed, converted to analog waveforms, and viewed. Simultaneous recording and viewing of analog waveforms from sensors, in addition to the CAN data, allows for checking the impact of noise and level changes on the communication data.
3 Multi-Channel Mixed Measurement of Various Signals Install your input modules according to your n Support for various measurement items (Using the optional input unit, and the optional differential probe for AC RMS voltage) specific needs Measurement target The plug-in units use an input amplifier structure and can be selected according to your measurement application. Additional input modules Voltage can be purchased separately and switched with existing units.
4 Touch Screen for Direct Operation Touch screen interface improves operating efficiency Buttons on the main body are kept to a minimum by utilizing touch screen technology. The high-definition 8.4-inch high-brightness TFT color LCD is the interface of choice for improving productivity by offering a more intuitive experience than traditional input methods.
5 Analyze Data with a Variety of Intelligent Functions Split screen, sheet display, event mark input, and jump functions indispensable for efficient analysis Split screen and sheet display functions are provided to support multiple channels. Individual display formats can be selected and an application can be assigned to each sheet for analysis, increasing productivity. ★ For long-term recordings, tag important points with event markers.
Measure the displacement-pressure relationship of a press machine or the pressure-flow rate of a pump Not only time-axis waveforms but also X-Y waveforms can be viewed. This function is also useful for collecting mechanical data, because X-Y Lissajous waveforms such as those of displacement, pressure, and flow rate can be drawn.
Basic specifications (product guaranteed for one year) Measurement function (high-speed recording) Measurement function High-speed function (high-speed recording) Up to 4 slots: User installable in any combination by plugging into the instrument [MR8901 ×4 units]: 16 analog channels + standard 8 logic channels + 2 pulse channels [MR8902 ×4 units]: 60 analog channels + standard 8 logic channels + 2 pulse channels Number of input units [MR8903 ×4 units]: 16 analog channels + standard 8 logic channels +
Calculation functions Other functions • Simultaneously make up to 8 calculations for any selected channels(s) Average value, Effective (rms) value, Peak to peak value, Maximum value, Time to maximum value, Minimum value, Time to minimum value, Period, Frequency, Rise time, Fall time, Area value, X-Y area value, Standard deviation, Specified level time, Specified time level, Numerical calculation Pulse width, Duty ratio, Pulse count, Time difference, Phase difference, High-level, Low-level, Four arithm
■ Options specifications (sold separately) Plug-in slot for the input units Dimensions, mass: Approx. 119.5 (4.70in) W × 18.8 (0.74in) H × 184.8 (7.28in) D mm, Approx. 190 g (6.7 oz) Accessories: Ferrite clamp ×2 VOLTAGE/TEMP UNIT MR8902 Number of channels: 15, for voltage measurement or temperature measurement (selectable for each channels) Functions Measurement target Input unit Measurement range ANALOG UNIT MR8901 Voltage Current 100 mV f.s. to 200 V f.s. STRAIN UNIT MR8903 1 mV f.s.
■ Options specifications (sold separately) Dimensions, mass: Approx. 119.5 (4.70in) W × 18.8 (0.74in) H × 151.5 (5.96in) D mm, Approx. 185 g (6.5 oz) Accessories: None CAN UNIT MR8904 Input CAN port CAN standards CAN interface Transmit ACK Terminator Baud rate Analyzed signal output channel Signal form Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.
Configuration of options Input modules (Install by inserting into the main unit. Can be replaced by user. Input cables are not supplied.