Datasheet

HiTESTER 3030-10
Basic tester with improved safety features
SPECIFICATIONS
DC Voltage range
0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)
Accuracy: ±2.5 % f.s.
AC Voltage range
12 V (9 k-ohm/V) Accuracy: ±4 % f.s.
30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s.
Average rectier effective value
Resistance range
0 to 3 k-ohm ( center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k
±3 % of scale length
DC Current range
60 μA/30 m/300 mA (300 mV internal voltage drop)
Accuracy: ±3 % f.s.
Other functions
Battery check: 0.9 to 1.8 V, load resistance 10 ohm
Safety considerations
Complies with EN61010 Installation Category III
(anticipated transient overvoltage 6000 V),
Pollution Degree 2
Power supply
R6P(AA) × 2 batteries
Dimensions, mass
95 mm(3.74 in)W × 141 mm(5.55 in)H × 39 mm(1.54 in)D,
280 g (9.9 oz)
Accessories
TEST LEAD (1), fuse (1), CARRYING CASE 9390 (1)
TEST LEAD
L9207-30
*HIGH-VOLTAGE PROBE 9017 (up to 30 kV DC)
*Note: Non-CE mark product
Options
CAT III 600V
l Protected against transient voltages up
to 250 V AC, preventing electric shock
accidents before they can happen
lDrop proof design withstands dropping
onto a concrete floor from a height of 1
meter
Analog Multimeters and Voltage Meters
MULTI TESTER 3008
For maintenance service
SPECIFICATIONS
DC Voltage range
6/30/60/300/600 V (20 k-ohm/V) Accuracy: ±2.5 % f.s.
AC Voltage range
6/30/150/300/600 V (10k-ohm/V) Accuracy: ±2.5 % f.s.
Average rectier effective value
Resistance range
0 to 10 k-ohm ( center scale 100 ohm), R × 1, R × 10, R × 100
±3 % of scale length
Safety considerations
Protection:1A rated, guaranteed current 50,000A high-power
fuse and 10 ohm resistor for restricting short circuit current
Power supply
R6P(AA) × 2 batteries
Dimensions, mass
94 mm(3.70 in)W × 134 mm(5.28 in)H × 56 mm(2.20 in)D,
350 g (12.3 oz)
Accessories
TEST LEAD 9060 (1), fuse (1), CARRYING CASE (1)
l Designed for maintenance of high
power lines
lDrop proof design withstands dropping
onto a concrete floor from a height of 1
meter
lHigh-power fuse protects up to 50,000A
l Supply current limiting resistance of
10-ohm restricts short circuit current
SAFETY HiTESTER 3258
Voltage measurement safety assured by
non
Metallic
contact testing
SPECIFICATIONS
AC Voltage range
(40 to 66Hz)
420.0 V
±1.5%rdg. ±5dgt.
600 V
380 V to 480 V
±2.0%rdg. ±5dgt.
481 V to 600 V
±5.0%rdg. ±5dgt.
Objects of Measurement
Insulated conductors (IV or CV equivalent, min. 100 mm
2
x-section), bare metal conductors
Note:Not usable on shielded conductors.
Power supply
LR6 alkaline battery × 6
Dimensions, mass
83W × 178H × 58D mm (2.01”W×10.83”H×1.48”D)
670 g (23.6 oz)
Accessories
Soft carrying case (1)
l Non-Metallic contact for optimum safety
lCapture the voltage value of covered
electric wires
lAlso ideal for metallic busbars and
terminals
l Optimized for 400V AC
circuits
To prevent electric shock, a fuse for protection up to a commercial
power supply of 250V is integrated into the internal circuitry of Model
3030-10. Please note that the fuse is not intended for preventing damage
to the unit.
The TEMP scale on Model 3030-10 is not effective without Model 9021-01
Temperature Probe, which has been discontinued.
Measure voltage on insulated
electric cables
HEADQUARTERS:
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568
http://www.hioki.com / E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION:
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: hioki@hiokiusa.com
All information correct as of Dec. 27, 2012. All specications are subject to change without notice. DMMsE8-36E Printed in Japan
DISTRIBUTED BY
HIOKI (Shanghai) SALES & TRADING CO., LTD.:
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: info@hioki.com.cn
HIOKI INDIA PRIVATE LIMITED:
TEL +91-731-6548081 FA X +91-731-4020083
E-mail: info@hioki.in
HIOKI SINGAPORE PTE. LTD.:
TEL +65-6634-7677 FAX +65-6634-7477
E-mail: info@hioki.com.sg
HIOKI KOREA CO., LTD.:
TEL +82-42-936-1281 FAX +82-42-936-1284
E-mail: info-kr@hioki.co.jp
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.