Data Sheet
Configuration of options
Note: Options described as ”factory-installed options” must be specified when ordering and cannot be installed by the user. Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
RECORDING PAPER 9231
A4 width 216 mm (8.50 in) × 30 m
(98.43 ft), 6 rolls
CARRYING CASE 9397-01
With casters for easier transport.
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
Other options
Printer options
MEMORY HiCORDER 8855
* The MEMORY HiCORDER
8855
cannot operate alone. You must install one
or more optional input modules in the unit.
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8950
VOLTAGE/CURRENT UNIT 8951
DC/RMS UNIT 8952
HIGH RESOLUTION UNIT 8953
-10
VOLTAGE/TEMPERATURE UNIT 8954
F/V UNIT 8955
PAPER WINDER 220H
Paper width 70 to 220 mm (2.76 to
8.66 inch), 100 V AC Only
PRINTER UNIT 8994
Factory-installed option. Printing width 200
mm (7.87 inch).
PC Software
PC Communication
FUNCTION UP DISK 9549
(POWER MONITOR)
Adds power monitor functions to the
MEMORY HiCORDER 8855.
3269
3273-50
3276
3274
3275
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
POWER SUPPLY 3272
Connect and power up to one CLAMP ON
PROBE to use in combination with voltage
input modules
POWER SUPPLY 3269
Connect and power up to four CLAMP ON
PROBEs to use in combination with voltage
input modules
3272
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
Note: The 3270 series can be directly
connected to the VOLTAGA/
CURRENT UNIT 8951.
Logic signal measurement
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.5
μsec, miniature terminal type)
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF
detection of AC/DC voltage
(miniature terminal type)
LOGIC PROBE 9327
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.1
μsec or higher, miniature terminal type)
CONVERSION CABLE 9323
Used for connecting the 9320/9321 and
8855 series MEMORY HiCORDERs,
because the terminal shapes are different.
* This cable is not required for the small-
terminal types 9327, 9320-01, and
9321-01.
Recommended Recommended
Recommended
Voltage measurement for use with general input modules
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultra-
flexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the ends
of test leads (9790)
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9197
For high voltage (up to 500 V), 1.8 m
(5.91 ft) length
CONNECTION CORD 9198
For low voltage (up to 300 V), 1.7 m
(5.58 ft) length
10:1 PROBE 9665
Max. rated voltage to earth is same as
for input module, max. input voltage 1
kV rms (up to 500 kHz), 1.5 m (4.92 ft)
length
100:1 PROBE 9666
Max. rated voltage to earth is same as
for input module, max. input voltage 5
kV peak (up to 1MHz), 1.5 m (4.92 ft)
length
Recommended
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
Tip Expanders
9790
-01
Tip Expanders
9790
-03
Tip Expanders
9790
-02
High-Voltage measurement for use with power supply
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC. Use
with either AC Adapter 9418-15, or
via Power Cord.
AC ADAPTER 9418-15
For powering Differential probe
9322, 100 to 240 V AC
POWER CORD 9328
Use to the 9322 from the Input modules
Not CE marked
PT 9303
Insulation transformer, 400 V or 200 V AC input,
10 V AC output, for AC power line measurement.
Required along with the Conversion Adapter 9199.
SENSOR UNIT 9555-10
Power supply unit for the 9272 to
the 9279 clamp sensors, except for
connecting to the 8951, for signal
output, the 9217 is necessary.
CONVERSION CABLE 9318
(to connect the 9272 - 9279 and
the 8951)
VOLTAGE/CURRENT UNIT 8951
UNIVERSAL CLAMP ON CT
9277
Observe waveforms from DC to distorted AC.
DC to 100kHz response, input 20A / output
2V AC
UNIVERSAL CLAMP ON CT
9278
Observe waveforms from DC to distorted AC.
DC to 100kHz response, input 200A / output
2V AC
UNIVERSAL CLAMP ON CT
9279
Observe waveforms from DC to distorted AC.
DC to 20kHz response, input 500A / output
2V AC
CLAMP ON SENSOR
9272
-10
Enables observation of AC current
waveforms. Input: 1 to 100kHz, selectable
20 and 200A rms ranges, 2V AC output
Not CE marked
CONVERSION CABLE 9318
to connect the 9272 to 9279 and the 8951
VOLTAGE/CURRENT UNIT 8951
LAN CABLE 9642
Straight Ethernet cable, supplied
with straight to cross conversion
cable, 5 m (16.41 ft) length
GP-IB CARD 9558
PCMCIA-compliant, cord length:
2m (6.6ft)
RS-232C CARD 9557
PCMCIA-compliant
LAN COMMUNICATOR 9333
Application software to create a LAN
connection
Compatible with Windows
95/98/Me, Windows NT
4.0/2000/XP
WAVE PROCESSOR 9335
Data conversion, print functions, waveform
display, compatible with Windows 95/98/Me,
Windows NT 4.0/2000/XP, and Windows
Vista 32-bit type.
Removable storage (CF card)
Supplied with PC
Card adapter
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
CONNECTION CORD 9217
Cord has insulated BNC connectors at
both ends, and connects to insulated
BNC connectors on input module.
1.7 m (5.58 ft) length
CONNECTION CORD 9165
Cord has metallic BNC connectors at
both ends, and connects to metallic BNC
connectors.
1.5 m (4.92 ft) length
Not CE marked
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
Not CE marked
Combination example (1)
Main unit with memory 32 MW
No. of CH.
2 ch + logic 16 ch 4 ch + logic 16 ch 6ch + logic 16ch 8ch + logic 16ch
Combination example (2)
Main unit with memory 128 MW
No. of CH.
2 ch + logic 16 ch 4 ch + logic 16 ch 6ch + logic 16ch 8ch + logic 16ch
Memory capacity normal 32
M-words, Printer less
8855 × 1 only
Input module
8950 × 2 8950 × 4 8950 × 6 8950 × 8
Expands memory to 4 times standard
size, 128 M-words, Printer installed
Memory Board 9645 × 1
Input module
8950 × 2 8950 × 4 8950 × 6 8950 × 8
Input cable
9198 × 2 9198 × 4 9198 × 6 9198 × 8
PRINTER UNIT 8994 × 1
Input cable
9198 × 2 9198 × 4 9198 × 6 9198 × 8
Current measurement *
Band width DC to 100 MHz class
MEMORY BOARD 9645
(128 Megaword total) Expands memory
to 4 times standard size. Specify upon
order, factory installation only.
MEMORY BOARD 9645-01
(512 Megaword total) Expands memory
to 16 times standard size. Specify upon
order, factory installation only.
HD UNIT 9663
Specify upon order, factory installation
only. (20GB)
Note: The MO and HD units cannot be
mounted on the unit at the same time.
MO UNIT 9646
Discontinued
Factory-installed option *Must specify when ordering
Current measurement
* To connect the clamp-on sensor via the conversion cable, Band
width DC to 100 kHz class