User Manual
129
────────────────────────────────────────────────────
7.3 STATUS1 Settings (REC&MEM)
────────────────────────────────────────────────────
7
.3.8 Setting the Additional Recording Function
Additional recording: OFF Additional recording: ON
1. Recording 25 divisions of waveform 1. Recording 25 divisions of waveform
2000 DIV(No memory expansion)
25DIV
2000 DIV(No memory expansion)
25DIV
2. Recording another 25 divisions of
waveform
2. Recording another 25 divisions of
waveform
T
he first set of measurement data is
d
iscarded, and recording of the second set o
f
m
easurement data starts again from the
b
eginning of memory.
25DIV
T
he first set of measurement data is
p
reserved, and recording of the second set
o
f measurement data starts after the first set
.
25DIV
T
he first and second sets of waveforms
c
an be observed by scrolling or printing the
w
aveform.
25DIV
・This records, regarding the memory as though it were recording paper.
・Without expansion memory, the last 1000 (64 M words: 5000) divisions of
waveform can be held in memory.
・The waveform can be scrolled and printed out.
Switching the additional recording on and off affects the use of memory as
shown below.