Data Sheet
Factory-installed option *Must specify when ordering
MEMORY BOARD 9599
Expands main unit memory by 4×,
Note: user installable this board
Note: The MO UNIT 9598 is
discontinued
Configuration of options
Note: Options described as ”factory-installed options” must be specified when ordering and cannot be installed by the user. Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to
cross conversion cable, 5 m (16.41 ft) length
PC Communication
Other options
LAN COMMUNICATOR 9333
Application software to create a LAN
connection
Compatible with Windows 95/98/Me,
Windows NT 4.0/2000/XP
PC Software
GP-IB CARD 9558
PCMCIA-compliant, cord length:
2m (6.6ft)
RS-232C CARD 9557
PCMCIA-compliant
LAN CARD
May not operate depending on the
environment., 10BASE-T
Not CE marked
Logic signal measurement
Voltage measurement for use with general input modules
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultra-
flexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the ends
of test leads (9790)
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9197
For high voltage (up to 500 V), 1.8 m
(5.91 ft) length
CONNECTION CORD 9198
For low voltage (up to 300 V), 1.7 m
(5.58 ft) length
10:1 PROBE 9665
Max. rated voltage to earth is same as
for input module, max. input voltage 1
kV rms (up to 500 kHz), 1.5 m (4.92 ft)
length
100:1 PROBE 9666
Max. rated voltage to earth is same as
for input module, max. input voltage 5
kV peak (up to 1MHz), 1.5 m (4.92 ft)
length
Recommended
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
Tip Expanders
9790
-01
Tip Expanders
9790
-03
Tip Expanders
9790
-02
High-Voltage measurement for use with power supply
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC. Use
with either AC Adapter 9418 -15, or
via Power Cord.
AC ADAPTER 9418-15
For powering Differential probe
9322, 100 to 240 V AC
POWER CORD 9324
Use to the 9322 from the logic terminal.
* Note that usage restrictions apply.
POWER CORD 9325
Use to the 9322 from the F/V UNIT
8940.
* Note that usage restrictions apply.
PT 9303
Insulation transformer, 400V or 200V AC input,
10V AC output, for AC power line measurement.
Required along with the Conversion Adapter 9199.
Not CE marked
Removable storage (CF card)
Supplied with PC
Card adapter
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
CONNECTION CORD 9217
Cord has insulated BNC connectors at both ends,
and connects to insulated BNC connectors on
input module. 1.7 m (5.58 ft) length
CONNECTION CORD 9165
Cord has metallic BNC connectors at
both ends, and connects to metallic BNC
connectors. 1.5 m (4.92 ft) length
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
Not CE marked
MEMORY HiCORDER 8826
*
The MEMORY HiCORDER
8826
cannot operate alone. You must
install one or more optional input modules in the unit.
Printer options
RECORDING PAPER 9229
264 mm (10.39 in) × 30 m (98.43 ft),
6 rolls set
RECORDING PAPER 9229
-01
perforated type, 264 mm (10.39 in) ×
30 m (98.43 ft), 6 rolls set
Combination example
Main unit with memory 16 MW
No. of channels
4 ch
+ logic 32 ch
8 ch
+ logic 32 ch
12 ch
+ logic 32 ch
16 ch
+ logic 32 ch
20 ch
+ logic 32 ch
24 ch
+ logic 32 ch
28 ch
+ logic 32 ch
32 ch
+ logic 32 ch
(normal choice of the input unit,
up to 200V AC direct input.)
8826 × 1
Input module
8936 × 2 8936 × 4 8936 × 6 8936 × 8 8936 × 10 8936 × 12 8936 × 14 8936 × 16
Input cable
9198 × 4 9198 × 8 9198 × 12 9198 × 16 9198 × 20 9198 × 24 9198 × 28 9198 × 32
Recommended
WAVE PROCESSOR 9335
Data conversion, print functions, waveform
display, compatible with Windows 95/98/Me,
Windows NT 4.0/2000/XP, and Windows
Vista 32-bit type.
3269
3273-50
3276
3274
3275
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
POWER SUPPLY 3272
Connect and power up to one CLAMP
ON PROBE to use in combination with
voltage input modules
POWER SUPPLY 3269
Connect and power up to four CLAMP
ON PROBEs to use in combination
with voltage input modules
3272
Current measurement *Connect directly to the analog input module
CLAMP ON PROBE 9018-50
Input from 10 to 500 A, 40 Hz to 3 kHz for
0.2 V AC output. BNC terminal
CLAMP ON PROBE 9132-50
Input from 20 to 1000 A, 40 Hz to 1 kHz for
0.2 V AC output. BNC terminal
SENSOR UNIT 9555-10
Power supply unit for the 9272 to
the 9279 clamp sensors, except
for connecting to the F/V unit
8940, for signal output 9217 is
necessary.
CONVERSION CABLE 9318
(To connect the 9272 - 9279
and the 8940)
F/V UNIT 8940
UNIVERSAL CLAMP ON CT
9277
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
UNIVERSAL CLAMP ON CT
9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A /
output 2V AC
UNIVERSAL CLAMP ON CT
9279
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
CLAMP ON SENSOR
9272
-10
Enables observation of AC current
waveforms. Input: 1 to 100kHz, selectable
20 and 200A rms ranges, 2V AC output
CONVERSION CABLE 9705
Use with the Conversion Cable 9318
to connect Model 9272-10 to the F/V
Unit 8940. (Not necessary for when
using the Model 9272 due to different
output wiring specifications.)
Not CE marked
CONVERSION CABLE 9318
To connect the 9272 to 9279 and the 8940
3273-50
Current measurement
* To connect the clamp-on sensor via the conversion cable, The
3274, 3275, and 3276 cannot be used for the F/V UNIT 8940
CONVERSION CABLE 9319
To connect the 3273-50 and the 8940
Note: cannot be used with the 3274, 3275,
3276 to connect the 8940 via this cable
9319
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8936
VOLTAGE/TEMP UNIT 8937
FFT ANALOG UNIT 8938
STRAIN UNIT 8939
F/V UNIT 8940
(8826 Ver. 2.10 or later can be used, Current probes with a serial number
of No. 1999-0338386 or later can be used, older types cannot be used.)
4ch ANALOG UNIT 8946
.......................................................(It cannot be used with the 8826.)
CHARGE UNIT 8947
.............................................. (Used with the 8826, Ver. 2.20 or later)
Recommended
LOGIC PROBE 9321
4 isolated channels, ON/OFF
detection of AC/DC voltage
(large terminal type)
LOGIC PROBE 9320
4-channel type, for voltage/contact
signal ON/OFF detection (response
time 0.5 μsec, large terminal type)