CHARGE UNIT 8947
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 1 hour of warm-up
time and zero-adjust; accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for acceleration measurement
Input connectors
Voltage input/integrated preamplifier input: metallic BNC connector
(for voltage input: input impedance 1MΩ, input capacitance 200pF or less)
Charge input: miniature connector (#10-32 UNF)
Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated
from the unit, the maximum voltage that can be applied between input channel and
chassis and between input channels without damage)
Suitable
transducer
Charge input: Charge-output type piezoelectric acceleration pick-up sensor
Internal preamp input: Acceleration pick-up sensor with an internal preamp
Measurement
range
Charge input
(miniature connector)
Internal pre-amp input
(BNC connector)
50m (m /s
2
)/DIV to 10k (m/s
2
)/DIV, 12 ranges × 6 types, charge input sensitivity:
0.1 to 10 pC/
(m/s
2
), integrated pre-amplifier input: 0.1 to 10 mV/(m/s
2
),
amplitude accuracy: ±2% of full scale, frequency characteristics: 1 to 50kHz,
+1/−3dB, low-pass filter: 500Hz/5kHz, pre-amplifier drive power source:
2mA ±20%, +15V ±5%, maximum input charge: ±500pC
(high-sensitivity setting,
6 ranges)
, ±50000pC (low-sensitivity setting, 6 ranges)
Measurement
range
Voltage input (BNC connector)
500μV to 2V/DIV, 12 ranges, DC amplitude accuracy: ±0.4% of full scale, frequency
characteristics: DC to 400kHz, +1/−3 dB, low-pass filter: 5Hz/500Hz/5kHz/100kHz,
input coupling: DC, GND, AC, Max. allowable input: 30Vrms or 60V DC
Measurement resolution
1/80 to 1/32 of measurement range (depending on measurement
sensitivity; installed in the 8826)
Highest sampling rate
1MS/s (simultaneous sampling in 2 channels)
Anti-aliasing filter
Integrated filter for suppressing aliasing distortion caused by
FFT processing (automatic cutoff frequency setting/OFF)
Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm,
approx. 310 g (10.9 oz) Accessories: None
LOGIC PROBE 9320
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
Function
Detection of voltage signal or relay contact signal for High/Low state recording
Input
4 channels (common ground between unit and channels), digital/contact input,
switchable
(contact input can detect open-collector signals), input impedance:
1MΩ
(with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to
+50V)
, pull-up resistance: 2kΩ (contact input: internally pulled up to +5V)
Digital input threshold
1.4V/2.5V/4.0V
Contact input
detection resistance
1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open)
and 1.5kΩ or lower
(short), 25kΩ or higher (open) and 8kΩ or lower (short)
Response speed
Detectable pulse width 500ns or lower
Max. allowable input
0 to +50V DC (the maximum voltage that can be applied across input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm
(0.98 ft), approx. 150 g (5.3 oz)
LOGIC PROBE 9321
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
Function
Detection of AC or DC relay drive signal for High/Low state recording
Can also be used for power line interruption detection
Input
4 channels (isolated between unit and channels), HIGH/LOW range switching
Input impedance: 100kΩ or higher
(HIGH range), 30kΩ or higher (LOW range)
Output (H)
detection
170 to 250V AC, ±DC (70 to 250V )
(HIGH range)
60 to 150V AC, ±DC (20 to 150V) (LOW range)
Output (L)
detection
0 to 30V AC, ±DC (0 to 43V)
(HIGH range)
0 to 10V AC, ±DC (0 to 15V) (LOW range)
Response time
Rising edge 1ms max., falling edge 3ms max.
(with HIGH range at
200V DC, LOW range at 100V DC)
Maximum allowable
input voltage
250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage
that can be applied across input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft),
approx. 320 g (11.3 oz)
DIFFERENTIAL PROBE 9322
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
Function
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
DC mode
For waveform monitor output, frequency characteristics: DC to 10MHz
(±3dB), amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3%
of full scale
(at max. 2000V DC) (full scale: 2000V DC)
AC mode
For detection of power line surge noise, frequency characteristics: 1kHz
to 10MHz ±3dB
RMS mode
DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz to
100kHz, response speed: 200ms or less
(400V AC), accuracy: ±1% of full scale
(DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000V AC)
Input
Input type: balanced differential input, input impedance/capacitance:
H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth:
when using grabber clip 1500V AC/DC
(CAT II ), 600V AC/DC (CAT III ),
when using alligator clip: 1000V AC/DC
(CAT II), 600V AC/DC (C AT III )
Maximum allowable
input voltage
2000V DC, 1000V AC (CAT II)
600V AC/DC (CAT III)
Output
Voltage divider for 1/1000 of input, BNC connectors (output switchable
for 3 modes DC, AC, RMS)
Power source
Use of the AC ADAPTER 9418-15 (12V DC)
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm
(1.51 ft), approx. 350 g (12.3 oz)
WAVE PROCESSOR 9335
Distribution media
One CD-R
Operating
environment
Computer equipped with Pentium (133 MHz) or better CPU and at least
32 MB of memory, and running under Windows 95/98/Me, Windows
NT 4.0/2000/XP, or Windows Vista 32-bit type
(recommended system:
Pentium (200 MHz) or better with at least 64 MB of memory)
Display functions
Waveform display/X-Y display/digital value display/cursor function/
scroll function/maximum number of channels (32 channels analog, 32
channels logic)/gauge display (time, voltage axes)/graphical display
File loading
Readable data formats (.MEM, .REC, .RMS, .POW)
Maximum loadable file size: Maximum file size that can be saved by
a given device (file size may be limited depending on the computer
configuration)
Data conversion
Conversion to CSV format, tab delimited, space delimited/data culling
(simple)/convert for specified channel/batch conversion of multiple files
Print functions
Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/
hard copy functions usable on any printer supported by operating system
Other
Parameter calculation/search/clipboard copy/launching of other
applications
LAN COMMUNICATOR 9333
Distribution media
One CD-R
Operating
environment
Computer equipped with Pentium (133 MHz) or better CPU, running
under Windows 95/98/Me or Windows NT 4.0/ 2000/XP operating
system, with network adapter installed and configured to use TCP/IP
protocol, and at least 64 MB of memory.
HiCORDER side
Standard LAN connector, LAN card
Communications
Ethernet, TCP/IP
Remote control
Remote control of MEMORY HiCORDER (by sending key codes and receiving
images on screen), print reports, print images from the screen, receive
waveform data in same format as waveform files from the MEMORY
HiCORDER (binary only)
Waveform data
acquisition
Accept auto-saves from the MEMORY HiCORDER, same for mat
as auto-save files of MEMORY HiCOR DER (binary only), print
automatically with a MEMORY HiCORDER from a PC. The
MEMORY HiCORDER's print key launches printouts on the PC
Waveform viewer
Simple display of waveform files, conversion to CSV format, Scroll
function, enlarge/reduce display, display CH settings.