Data Sheet

CONNECTION CORD 9197
For high voltage (up to 500 V), 1.8 m
(5.91 ft) length
CONNECTION CORD 9198
For low voltage (up to 300 V), 1.7 m
(5.58 ft) length
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
Tip Expanders
9790
-01
Tip Expanders
9790
-03
Tip Expanders
9790
-02
MEMORY HiCORDER 8808
-01 (4 ch)
* Input cable for measurement use is not provided. Please
purchase the optional cable.
MEMORY HiCORDER 8807
-01 (2 ch)
* Input cable for measurement use is not provided. Please
purchase the optional cable.
Configuration of options Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
Current measurement *50/60 Hz line use Current measurement *High precision type
Current measurement *For Oscilloscope, wide-band frequency type
Power Supply *Sold separately
Printer options
PAPER WINDER 220H
Paper width: 70 to 220 mm (2.76 to 8.66 in),
using special-purpose AC adapter
Combination example (1)
Main unit with memory 256 kW
Printer AC adapter Battery pack Input cable
Combination example (2)
Main unit with memory 256 kW
Printer AC adapter Battery pack Input cable
4 ch + logic 8 ch
Printer less
8808-01 × 1 Not use 9418-15 × 1 9447 × 1 9198 × 4
4 ch + logic 8 ch
With Printer unit
8808-01 × 1 8992 × 1 9418-15 × 1 9447 × 1 9198 × 4
SENSOR UNIT 9555-10
Power supply unit for the 9272
to the 9279 clamp sensors, for
signal output 9217 is necessary.
UNIVERSAL CLAMP
ON CT 9277
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
UNIVERSAL CLAMP
ON CT 9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A
/ output 2V AC
UNIVERSAL CLAMP
ON CT 9279
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
CLAMP ON SENSOR
9272
-10
Enables observation of AC current
waveforms. Input: 1 to 100kHz,
selectable 20 and 200A rms ranges, 2V
AC output
CLAMP ON
PROBE 9018
-50
Enables observation of
AC current waveforms.
Input: 40 Hz to 3 kHz,
selectable 10 to 500 A ranges,
Output: 0.2 V AC/ range
CLAMP ON PROBE
9132
-50
Enables observation of
AC current waveforms.
Input: 40 Hz to 1 kHz,
selectable 20 to 1000 A
ranges, Output: 0.2 V AC/ range
CLAMP ON LEAK HiTESTER
3283
For leakage current measurement,
includes 10 mA to 200 A ranges,
with analog output of 1 V f.s. DC,
and waveform monitor output of 1
V f.s. AC at 40 Hz to 2 kHz. Requires
the AC adapter 9445-02/-03
AC ADAPTER 9445-02/-03
With the 3283, continuous use.
For USA, Canada: 9445-02, For
EU: 9445-03.
OUTPUT CORD 9094
Required along with the
9199 adapter to connect
the 3283 to the 8808
series.
Carrying case
CARRYING CASE 9648
Hard case type, for storing options
CARRYING CASE 9391
Soft case type, for storing options.
Holds more options than the 9648 hard
case.
PRINTER UNIT 8992
Printing width 100 mm (3.94 in),
used together with the 8807-01,
8808-01 main body
BATTERY PACK 9447
7.2 V, 2400 mAh
CHARGE STAND 9643
Independent of the 8808 series main
unit, use with the AC ADAPTER
9418-15 to charge one Model 9447.
AC ADAPTER 9418-15
Universal 100 to 240 V AC,
12 V DC/ 2.5 A output
The units can be operated using the supplied LR6/
AA alkaline batteries but use of the optional
AC
ADAPTER
9418-15 or BATTERY PACK 9447 (the
AC ADAPTER 9418-15 is necessary for recharging)
is recommended. Manganese batteries cannot be
used. Use of commercially available rechargeable
batteries instead of the original battery pack may
result in damage to the unit.
High-Voltage measurement for use with power supply
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC. Use
with the AC Adapter 9418-15, for
power supply.
AC ADAPTER 9418-15
For powering Differential probe
9322, 100 to 240 V AC.
Not CE marked
PT 9303
Insulation transformer, 400V or 200V AC input,
10V AC output, for AC power line measurement.
Required along with the Conversion Adapter 9199.
PC Software
Logic signal measurement
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF
detection of AC/DC voltage
(miniature terminal type)
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.5
µsec, miniature terminal type)
CONVERSION CABLE 9323
Used for connecting the 9320/9321 and
8808 series MEMORY HiCORDERs,
because the terminal shapes are different.
* This cable is not required for the small-
terminal types 9327, 9320-01, and
9321-01.
3269
3273-50
3276
3274
3275
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
POWER SUPPLY 3272
Connect and power up to one CLAMP
ON PROBE to use in combination with
the 8808 series.
POWER SUPPLY 3269
Connect and power up to four CLAMP
ON PROBEs to use in combination
with the 8808 series.
3272
Not CE marked
Recommended
Not CE marked
RECORDING PAPER
9234
112 mm (4.41 in) × 18 m
(59.06 ft), 10 rolls set
Not CE marked
LINE SPLITTER CT101A
For 100 V/ 15 A, convenient for
measuring 100 V AC line current with
clamp-on probe
Other options
CONNECTION CORD 9217
Cord has insulated BNC connectors
at both ends, and connects to
insulated BNC connectors on input
terminal. 1.7 m (5.58 ft) length.
CONNECTION CORD 9165
Cord has metallic BNC connectors at
both ends, and connects to metallic
BNC connectors. 1.5 m (4.92 ft)
length.
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
Not CE marked
RS-232C CABLE 9612
Mini DIN 9-pin - Dsub 9-pin, Cable
length 1.5 m (4.92 ft) length.
Not CE marked
Removable storage (CF card)
Supplied with PC
Card adapter
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultra-
flexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the ends
of test leads (9790)
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
Recommended
Voltage measurement
Input cable for measurement use is not provided.
Please purchase the optional cable.
WAVE PROCESSOR 9335
Data conversion, print functions, waveform
display, compatible with Windows 95/98/Me,
Windows NT 4.0/2000/XP, and Windows
Vista 32-bit type.