3
Options
9691 CLAMP-ON AC/DC SENSOR (100 A)
9692 CLAMP-ON AC/DC SENSOR (200 A)
9693 CLAMP-ON AC/DC SENSOR (2000 A)
9445-02 AC ADAPTER
9445-03 AC ADAPTER (EU)
9094 OUTPUT CABLE
9400 CARRYING CASE
9199 CONNECTOR ADAPTER (BNC-to-Banana [female])
Measurement is not available with only the 3290 or 3290-10 CLAMP-ON AC/DC HiTESTER.
A CLAMP-ON AC/DC SENSOR (Model 9691, 9692 or 9693) must also be purchased
separately.
Mode
Response time setting
DC
1 < f < 10Hz 10 < f < 45Hz 45 < f < 66Hz
±1.8%rdg.±10dgt.
±1.8%rdg.±5dgt.
FAST
NOMAL
SLOW
FAST
NOMAL
Range
2000 A
66Hz < f < 1kHz
SLOW
±1.3%rdg.±8dgt.
±2.3%rdg.±8dgt.
2000 A
±1.3%rdg.±3dgt.
±2.3%rdg.±3dgt.
200.0 A
200.0 A
AC MEAN
(only 3290)
±2.3%rdg.±8dgt.
±1.8%rdg.±12dgt.
(when AC + DC is set only)
±1.3%rdg.±8dgt. ±2.3%rdg.±8dgt.
200.0 A
±2.3%rdg.±3dgt.
±1.3%rdg.±3dgt. ±2.3%rdg.±3dgt.
±1.8%rdg.±7dgt.
(when AC + DC is set only)
2000 A
AC+DC
AC RMS
DC
Combined accuracy with 9693
Measurement frequency f
Mode
Response time setting
DC
1 < f < 10Hz
10 < f < 45Hz 45 < f < 66Hz
DC
±1.3%rdg.±10dgt.
±1.3%rdg.±5dgt.
AC+DC
AC RMS
FAST
NOMAL
SLOW
FAST
NOMAL
66Hz < f < 1kHz
Range
20.00 A
200.0 A
20.00 A
200.0 A
SLOW
AC MEAN
(only 3290)
20.00 A
±1.3%rdg.±8dgt. ±2.3%rdg.±8dgt.
200.0 A
±1.3%rdg.±3dgt. ±2.3%rdg.±3dgt.
Measurement frequency f
Combined accuracy with 9691 or 9692
Model 3290 and 3290-10 Specifications (accuracy guaranteed at 23 ±5°C(73 ±9°F), 80% RH or less, non-condensating) Period of guaranteed accuracy: 1 year
±1.3%rdg.±12dgt.
(when AC + DC is set only)
±1.3%rdg.±8dgt.
±1.3%rdg.±8dgt.
±2.3%rdg.±8dgt.
(9691: up to 500Hz)
±1.3%rdg.±7dgt.
(when AC + DC is set only)
±1.3%rdg.±3dgt.
±1.3%rdg.±3dgt.
±2.3%rdg.±3dgt.
(9691: up to 500Hz)
Output rate:
(1) Rms current (REC_A): 2 V DC/range; (2) Current waveform (MON):
2 V/range; (3) Frequency (REC_Hz)
*1
: 1 V DC/range (*1. 3290 only)
Combined output connectors (OUT1 & OUT2
*2
):
(1) Current waveform (MON / MON.FL
*1
) & rms current (REC);
(2) Current waveform (MON / MON.FL
*1
) & low-battery detection (B.Lo)
(3) Rms current (REC) & low-battery detection (B.Lo)
(4) Frequency (REC) & rms current (REC) (3290 only)
*1. MON.FL is with fc = 1 Hz filter on,
*2. OUT2 of the 3290-
10 is total integral value (Ah), selected from positive, negative or total
value
Operating temperature and humidity: 0 to 40°C (32 to 104°F) @80% RH or
less (non-condensating) Storage temperature: -10 to 50°C (14 to 122°F)
(non-condensating)
Operating environment: up to 2000m ASL, indoors
Power source: Four AA-size (LR6) alkaline batteries, or AC adapter
Model 3290-
10 also accepts 8.4 to 15.6 V external DC power Max.
power consumption: 500 mVA (using batteries)
Battery life: approx. 22h
(continuous operation)
Applicable safety standards EMC: EN61010-1:2001, EN61326:1997+A1:1998+
A2:2001, EN61000-3-2:2000, EN61000-3-3:1995+A1:2001
External dimensions, weight: approx. 155W (6.10") × 98H (3.86") × 47D
(1.85") mm, approx. 545 g (19.2oz.)
Supplied accessories: Carrying strap
(1), AA-size (LR6) alkaline batteries (4)
Provided functions Zero Adjustment (DC and AC+DC) Data
Hold
Setting Saving Function:Saves the state of settings Key Lock
Battery Check Auto Power Off: about 10 minutes after last key
operation, beeper warning available Beeper sound on/off
Temperature characteristic: 0.1 × Specified Accuracy/°C (@0 to 40°C)
(0.18 × Specified Accuracy/°F (@32 to 104°F))
Function display: 21-segment bar graph, over-range (O.L.), low-battery
warning (B), Hold (HOLD), auto power off (APS)
Measurement response time: (1) FAST (0.2 s) for 45+ Hz; (2) NORMAL
(0.8 s) for 10+ Hz); (3) SLOW (8.0 s) for 1+ Hz)
* Input: The time for analog output to stabilize after transition from 0 R 90% or from
100 R 10%, setting AC (RMS) or AC+DC
Display refresh rate: (1) NORMAL: twice per second; (2) SLOW: once
per three seconds; (3) FAST: four times per second (ten times per
second for 3290-10; (4) Bar graph display: 4 times per second
Zero suppression: 5 counts
Range switching: Auto/manual
Crest factor: 2.5 or less, or the same or less than peak value of
connected sensor
Output impedance: 100 Ω or less
±2.0%rdg.±3dgt.
(when AC + DC, SLOW is set only)
±2.0%rdg.±8dgt.
(when AC + DC, SLOW is set only)
±3.0%rdg.±3dgt.
(when AC + DC, SLOW is set only)
±3.0%rdg.±8dgt.
(when AC + DC, SLOW is set only)
Frequency range
(accuracy range)
Maximum display
Accuracy
10.00Hz (1.00 to 10.00Hz)
12.50Hz
100.0Hz (10.0 to 100.0Hz)
125.0Hz
1000Hz (100 to 1000Hz)
1000Hz
±1.0%rdg.±1dgt.
±0.3%rdg.±1dgt.
3290
-10
Specifications Accuracy
Integral value display Current measurement accuracy ±1 dgt
Measurement time
Not more than ±0.2 s deviation per hour (@23°C(73°F))
Output connector voltage Display accuracy ±2 mV
Extension Cables Available by Special Order
Connects from the standard 2m (6.52ft) sensor cable to the 3290 or 3290-10
(available lengths are 5, 10, 20, 30, 50 and 100m (16.4, 32.8, 65.6, 98.4, 164.1 and
328.1ft))