Data Sheet
10
Demand calculation function
Settings
:
Analysis start time/period
:
Set the year, month, day, hours, minutes,
and seconds. /1 to 31 days
Demand interval settings :
5, 10, or 30 minutes, 1, 2, 3, 6, or 12 hours
Display method and calculation items :
Demand graph
(for consumption only)
, Average demand
(average demand value
for the specified analysis period)
, Maximum demand
(maximum demand value for the
specified analysis period)
, Load ratio
(average demand/maximum demand × 100 [%])
ITIC curve display function
Display function : Plot event points on limited value curve (points indicating
swell/dip/interruption occurrence period and voltage)
Percent of nominal voltage: Maximum swell voltage or residual voltage ratio against
official voltage
Violation count display : Number of upper-limit violations, number of lower- limit
violations, and total number of events
Limit curve selection
: ITIC curve or user-defined curve (any setting)
EN50160 display function
Screen display : Overview/Harmonic/Signaling/Measurement result sorting
Copy function
Copy content
:
Saves the various screens in BMP format
Print function
Print format: Prints screen images, Paper size: A4 and Letter, Print preview: Yes
CSV format conversion function
Screens that can be converted
:
TIME PLOT and event waveform screens
Conversion settings
:
Specified interval conversion (TIME PLOT screen only)
Conversion setting selection (TIME PLOT screen only)
Report creation function
Output format : Output setting contents can be printed, or saved as a rich text file.
(1) Automatic output :
RMS voltage fluctuation graph, worst case, maximum/minimum
list, total harmonic voltage distortion graph, Overview and
Signaling data of EN50160, and all event detail list.
(2) Arbitrary output : Includes, in addition to automatic output, RMS current
fluctuation graph, transient waveform, total harmonic current
distortion graph, Harmonic and result classification data of the
EN50160, and settings list.
(3) Detailed output : Voltage fluctuation, RMS fluctuation, harmonics fluctuation, and
interharmonics fluctuation.
Settings save function
Save user-defined curves, setting for sorting measurement result, report setting, etc.
Download function
Download data from the 3196 via LAN.
3196 Specifications
-2. Basic specifications
Power quality measurement
standards conformance
:
IEC61000-4-30:2002,
IEEE1159,
EN50160:1999
Clock functions
:
Auto calendar, auto leap year, 24-hour clock
Real-time clock accuracy
:
Within ±0.3 s/day (when the 3196 is turned on)
Internal memory capacity for data
:
13 MB (time series and event data)
Maximum recording interval
:
1 month (internal memory)
Measurement time control
:
Manual/Specified time
Time series data settings
Recording item setting patterns
:
Power, P&Harm, and ALL DATA
MAX/MIN/AVE values
:
AVE values, ALL values (maximum,
minimum, and average values)
Interval selections
:
1, 3, 15, or 30 seconds, 1, 5, 10, 15, or
30 minutes, 1 or 2 hours
Event settings
Event settings
:
All measurement settings except
flicker and inter-harmonics
Event threshold value setting
:
OFF or desired numerical value
Maximum number of recording events
:
100 (internal memory)
(Simultaneous events count as 1 event.)
Power supply
:
12 V DC from the 9458 AC ADAPTER or 9459 BATTERY PACK
Maximum rated power
:
40 VA
Continuous operating time with battery :
Approximately 30 minutes
(9459 battery pack)
External dimensions
:
Approximately 298W (11.73") × 215H (8.46") × 67D
(2.64") mm (not including projections)
Mass
:
Approximately 2.25 kg (79.4 oz.) (including 9459 battery pack)
-1. Measurement and recording items
Recording item
Power
P&Harm
ALL_D
Recording item
Power
P&Harm
ALL_D
Transient overvoltage
❍
❍
❍
Voltage unbalance factor
❍
❍
❍
Voltage swell
❍
❍
❍
Current unbalance factor
❍
❍
❍
Voltage dip
❍ ❍
❍
Harmonic voltage
×
❍
❍
Instantaneous interruption
❍
❍
❍
Harmonic current
×
❍
❍
Frequency
❍ ❍
❍
Harmonic power
×
❍
❍
RMS voltage
❍
❍
❍
Harmonic voltage-current phase difference
×
❍
❍
RMS current
❍
❍
❍
Inter-harmonic voltage
×
×
❍
Voltage peak
❍
❍
❍
Inter-harmonic current
×
×
❍
Current peak
❍
❍
❍
Total harmonic voltage distortion factor
❍
❍
❍
Effective power
❍
❍
❍
Total harmonic current distortion factor
❍
❍
❍
Apparent power
❍
❍
❍
Total inter-harmonic voltage distortion factor
×
×
❍
Reactive power
❍
❍
❍
Total inter-harmonic current distortion factor
×
×
❍
Power factor/Displacement power factor
❍
❍
❍
K factor
❍ ❍
❍
Flicker (∆V10/Pst, Plt)
❍
❍
❍
* Select from a total of six different patterns when recording data. These consist of three available data patterns
(Power, P&Harm, or ALL DATA), combined with two patterns, AVE and ALL (maximum, minimum, and average), of
detailed data for each measurement item.
9624 /
-10
Specifications
-1. Function specifications
Data loading functions
Data that can be loaded
:
Binary data recorded using the 3196
SET files
(Settings data)
, ITV files
(TIME PLOT data)
,
EVT files
(Event data (lists, voltage and current waveforms,
transient waveforms, numerical values)
, FLC files (Flicker
data
(∆V10, IEC)
), TRN files
(Transient waveforms),
EN50160. files (EN50160 dasta),
EVENT.EN files (EN50160 Event data)
Maximum data capacity
:
Up to 528 MB
Data display functions
SYSTEM display function
Screen display
:
SYSTEM (settings) content screen
TIME PLOT display function
Screen display
:
RMS fluctuation, voltage fluctuation, harmonic
fluctuation, inter-harmonic fluctuation
Number of display screens
:
Up to 4 screens
Cursor function
:
A and B cursors (interval calculation function provided)
EVENT list display function
Screen display
:
EVENT list content display
Display method selection
:
Order events occurred in, or order of priority
EVENT data display function
Display function
:
Display the event data selected in the EVENT list
display screen
Screen display
:
Display one of the following screens ((1) to (4))
(1)Waveform display :
Select from the voltage/current waveform, 4-channel
voltage waveform, 4-channel current waveform, and
voltage/transient overvoltage waveform displays.
(2)Vector display :
Select from the harmonic RMS value and phase angle
displays.
(3)DMM display :
Displays power, voltage, and current values.
(4)Harmonics display :
Select from the harmonics bar graph and list displays.
Cursor function
:
A and B cursors (interval calculation function provided)
for the waveform display screen
Positive/ Negative/ Zero phase calculation function
:Display voltage and current of the positive phase, negative
phase, and zero phase.(In vector display screen, this is conducted
during the 3P4W wiring analysis.)
Flicker graph Display function
Screen
display
:
∆V10
Flicker graph or IEC Flicker graph
Cursor function
:
A and B cursors (interval calculation function provided)
EVENT voltage fluctuation graph Display function
Cursor function
:
A and B cursors (interval calculation function provided)
Integral power consumption calculation function
Settings
:
Analysis start time/period
:
Set the year, month, day, hours, minutes,
and seconds. /1 to 31 days
Display method and calculation items :
Integral power consumption graph, Integral power consumption (consumption +
regeneration, and cursor measurement functions provided), Maximum integral power
consumption (final integral power consumption for the specified analysis period)
-2. Basic specifications
Supplied accessories
:
CD-R × 1
Operating environment
:
PC/AT-compatible devices
OS
:
English or Japanese versions of the following
• Microsoft Windows 95
(9624 only, OSR2 or later versions
only supported, Internet Explorer 3 or later required)
• Microsoft Windows 98, Me, NT 4.0, 2000 or XP
Memory
:
At least 128 MB
(Items in blue ■ symbolize specifications unique to Model 9624
-10