3196 POWER QUALITY ANALYZER Power Measuring Instruments Investigate All Your Power Quality Problems ■ Remote control and data collection via LAN modem ■ A full range of clamp sensors (Seven models with ratings from 5 to 5000 A AC) ■ 9624 PQA-HiVIEW, 9624-10 PQA-HiVIEW PRO software for flexible PC analysis ■ Power waveform observation ■ Abnormal waveform recording ■ Harmonic measurement ■ Flicker measurement ■ Power measurement All in a single unit ! EN50160 IEC61000-4-30 9624-10 PQA-HiVIEW PRO Compatibl
Capture all power anomalies without fail! Problems with power quality are all around us Have you ever experienced any of the following ? • • • • • Flickering lights Light bulbs burn out quickly Electronic office equipment does not function properly Sometimes devices operate abnormally Overheating in facilities using condensers fitted with reactors • 3E (electrical overload, reverse phase, or phase loss) relays sometimes trip These types of problems and others are often due to degraded power quality.
Supports data analysis with a wide range of functions! The 3196 measures, records and analyzes power line quality Full compatibility to 400Hz circuits Features (Please specify inspection data sheet requirements for 400 Hz test points at time of order.) ■ Supports single-phase 2-wire, single-phase 3-wire, three-phase 3-wire and three-phase 4-wire systems. Further, the unit has an extra input channel providing enhanced analysis capabilities.
Real-time data display for power supplies Display waveform, vector, DMM, and harmonic data in real-time The VIEW screen displays voltage/current waveforms, vector diagrams, DMM values (voltage, current, and power), and harmonic data. All data can be measured and processed simultaneously, and power conditions such as distortion factor, K factor, and the unbalance factor for three-phase lines can be monitored using the various data displays.
Capture anomalies while using time series measurement to monitor power lines Simultaneous time series monitoring for RMS fluctuations, voltage fluctuations, harmonics fluctuations, and flickering RMS fluctuation, voltage fluctuation, harmonic fluctuation, and flicker (IEC and ∆V10) time series data is displayed on the TIME PLOT screen.
Use event data to analyze the cause of power anomalies! Display the details for power anomalies captured using event triggers You can capture a variety of power anomalies by setting the individual trigger levels on the event setting screen. Captured data is displayed in the event list. This enables you to quickly confirm detailed data for phenomena (such as date/time, waveforms, RMS values, and harmonics), that are the source of problems, and effectively assess the cause of the problem.
Remote measurement is simplified using the HTTP server function Real-time measurement/control and download measurement data over the Worldwide Web ■ The HTTP server function as a standard feature makes remote measurement even more convenient You can perform remote observation and control using an ordinary Web browser, such as Internet Explorer, without the need for special software. Further, you can download measurement data that has been saved onto a PC card.
Choose from 2 Easy-to-Use Application Software Packages for Further Data Analysis 9624 PQA-HiVIEW & 9624-10 PQA-HiVIEW PRO Features ■ Viewer function Use this function to display screens similar to those used for the 3196. Select from the TIME PLOT screen (voltage fluctuation, RMS fluctuation, harmonic fluctuation, inter-harmonic fluctuation), event list screen, event data screen (waveforms, vectors, DMM, harmonics, event details), ∆V10 screen(Japanese standard), or settings screen.
Analyze power consumption and demand using acquired data ■ Integral power consumption analysis and demand analysis screens These screens allow you to calculate measurement data and display it in the integral power consumption graph or demand graph. (Use them to display the maximum demand, average demand, and load ratio values.) Further, you can confirm the power data for a specific interval using the cursor function. General power consumption is displayed.
9624 /-10 Specifications (Items in blue ■ symbolize specifications unique to Model 9624-10, and are not available in the standard Model 9624.) -1.
3196 Specifications (Guaranteed accuracy period : 6 months / Certain specifications vary when measuring 400Hz circuits. Please inquire with your HIOKI distributor for details.) -3.
■ Option Specifications Clamp On Sensors 9694 9661 9660 Cord length: 3 m (9.84 ft) Cord length: 3 m (9.84 ft) 9669 Cord length: 3 m (9.84 ft) Cord length: 3 m (9.84 ft) Appearance Primary current rating Output voltage CAT III 300V CAT III 300V CAT III 600V CAT III 600V 100 A AC 500 A AC 1000 A AC 5A AC 10 mV/A AC 1 mV/A AC 1 mV/A AC 0.5 mV/A AC ±0.3% rdg. ±0.02% f.s. ±0.3% rdg. ±0.02% f.s. ±0.3% rdg. ±0.01% f.s. ±1.0% rdg. ±0.01% f.s.