Operating instructions
2.4 Information displayed during operation
LED The LED does not light. The tool is switched off.
The LED does not light. The batteries are exhausted.
The LED does not light. The batteries are inserted incorrectly.
The LED lights constantly. The laser beam is switched on. The tool
is in operation.
The LED blinks twice every
10 seconds (pendulum not
locked) or every 2 seconds
(pendulum locked).
The batteries are almost exhausted.
The LED blinks. The tool is switched off but the pendu-
lum is not locked.
Laser beam The laser beam blinks twice
every 10 seconds (pendu-
lum not locked) or every 2
seconds (pendulum locked).
The batteries are almost exhausted.
The laser beam blinks five
times and then remains per-
manently on.
Automatic power-off has been deactiv-
ated.
The laser beam blinks rapidly. The tool is unable to level itself (outside
the self-leveling range).
The laser beam blinks every 2
seconds.
Inclined line operating mode. The pen-
dulum is locked, as a result of which the
lines are not leveled.
3 Accessories
Designation
Short designation
Description
Tripod PMA 20
Target plate PMA 54/55
Target plate PRA 50/51
Laser receiver PMA 31
Hilti toolbox
Laser visibility glasses PUA 60 The laser visibility glasses are not
protective glasses and thus do not
protect the eyes from laser beams.
As the laser visibility glasses restrict
color vision, they should be worn only
when working with the PM 4-M laser
tool. Do not wear the laser visibility
glasses while driving a vehicle on a
public road.
4 Technical data
Right of technical changes reserved.
Range of the lines and intersection point without laser receiver: 10 m
with laser receiver: 50 m
Accuracy
1
±2 mm at 10 m
1
Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810F).
en
3
Printed: 08.07.2013 | Doc-Nr: PUB / 5130903 / 000 / 02