Installation Guide
16
en
•
Push release trigger (1), retract plunger (2) and insert foil pack holder
with foil pack into the appropriate Hilti dispenser (3).
•
See Table VI for the selection of the most suitable HIT dispenser.
0
0
•
Observe the Instructions for Use of the mortar for the amount of mortar
that has to be discarded.
•
The foil pack is self opening when dispensing begins.
•
Do not pierce the foil pack manually (this can cause system failure).
•
After changing a mixer, the first trigger pulls must be discarded.
•
For each new foil pack a new static mixer must be used.
•
Inject the mortar from the back of the borehole by slowly withdrawing
the mixer incrementely after each trigger pull, after controlling that the
depth of the borehole corresponds to the design value.
•
Important! Use extensions for deep holes, as explained under special
case.
•
Fill holes approximately 2/3 full, or as required to ensure that the annu-
lar gap between the anchor/rebar and the concrete is completely filled
with mortar over the entire embedment length.
Insert foil pack holder with foil pack into dispenser
Discard initial amount of mortar
Inject mortar into borehole starting from the back of the borehole without forming air voids
02_BA_HIT_Profi_P1_en.qxd 13.12.2006 13:37 Uhr Seite 16