Installation Guide

15
en
Special Case: Manual Cleaning
0
0
4x
Blowing out
The Hilti manual pump may be used for blowing out boreholes up to
diameters d
s
16 mm (5/8") and borehole depths up to
inst
250 mm
(10") (please contact Hilti for further references).
Blow out at least 4 times from the back of the borehole.
Brushing
Brush the borehole 4 times with an appropriately sized round steel
brush. See above for details.
Blowing out
Blow out at least 4 times from the back of the borehole. See above for
details.
4. Injection of mortar
Observe the instructions for use of the dispenser.
Check foil pack holder for proper function.
Put foil pack into foil pack holder.
Do not use damaged foil packs/ holders.
Use the static mixer that is delivered with the mortar.
Attach the static mixer tightly on to the manifold before starting to dis-
pense.
Do not modify the static mixer.
Insert foil pack in foil pack holder
Tightly attach mixer to foil pack manifold