Instructions / Assembly

Mechanical Anchoring Systems
3.3.12 HLC Sleeve Anchor
338
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaƱol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2011
HLC-AC 1/4 X 1-3/8
Nut Configuration
Outside diameter of sleeve, see
tables for threaded bolt diameter
Definition of Nomenclature
A: the overall length from bottom
of washer to end of sleeve
3.3.12.5 Ordering Information
A
A
A
Round Head Slotted (RS)
Description
Bit Diameter
1
In.
Bolt Diameter
In.
Minimum
Embed. Depth
in. (mm)
Fastens
Materials Up To
in. (mm) Box Qty
HLC-RS 1/4 x 1-1/4
1/4 3/16
1 (25)
1/4
(6.4) 100
HLC-RS 1/4 x 2
1/4 3/16
1 (25) 1 (25) 100
HLC-RS 1/4 x 4
1/4 3/16
1 (25) 3 (76) 100
Bolt Head (H)
Description
Bit Diameter
1
In.
Bolt Diameter
In.
Minimum
Embed. Depth
in. (mm)
Fastens
Materials Up To
in. (mm) Box Qty
HLC-H 5/16 x 1-5/8
5/16 1/4
1 (25)
5/8
(16) 100
HLC-H 5/16 x 2-5/8
5/16 1/4
1 (25)
1-5/8
(41) 100
HLC-H 3/8 x 1-7/8
3/8 5/16 1-1/4
(32)
5/8
(16) 50
HLC-H 3/8 x 3
3/8 5/16 1-1/4
(32)
1-3/4
(44) 50
HLC-H 1/2 x 2-1/4
1/2 3/8 1-1/2
(38)
3/4
(20) 50
HLC-H 1/2 x 3
1/2 3/8 1-1/2
(38)
1-1/2
(38) 25
HLC-H 1/
2 x 4
1/2 3/8 1-1/2
(38)
2-1/2
(64) 25
Flat Phillips Head (FPH)
Description
Bit Diameter
1
In.
Bolt Diameter
In.
Minimum
Embed. Depth
in. (mm)
Fastens
Materials Up To
in. (mm) Box Qty
HLC-FPH 1/4 x 1-3/8
1/4 3/16
1 (25)
3/8
(10) 100
HLC-FPH 1/4 x 2
1/4 3/16
1 (25) 1 (25) 100
HLC-FPH 1/4 x 3
1/4 3/16
1 (25) 2 (51) 100
HLC-FPH 1/4 x 4
1/4 3/16
1 (25) 3 (76) 100
HLC-FPH 3/8 x 2-7/8
3/8 5/16 1-1/4
(32)
1-1/2
(38) 50
HLC-FPH 3/8 x 4
3/8 5/16 1-1/4
(32)
2-3/4
(70) 50
HLC-FPH 3/8 x 5
3/8 5/16 1-1/4
(32)
3-3/4
(95) 25
HLC-FPH 3/8 x 6
3/8 5/16 1-1/4
(32)
4-3/4
(120) 25
1 Hilti carbide tipped drill bits
3.3.12.4 Installation Instructions
Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded on-line
at www.us.hilti.com (US) and www.hilti.ca (Canada) -- "Service/Technical Info >> Technical Downloads >> Anchoring Systems".
Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to
achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not
addressed in the IFU.