Use and Care Manual
Laser beam Blinks twice every 10
seconds (pendulum not
locked) or every 2 seconds
(pendulum locked).
The batteries are almost exhausted.
Blinks five times and then
remains on permanently.
Automatic power-off has been deac-
tivated (see section “Deactivating the
automatic power-off function”.
Blinks with a high frequency. The tool is unable to level itself (outside
the self-leveling range).
Blinks every 2 seconds. Inclined line operating mode. The pen-
dulum is locked, as a result of which the
lines are not leveled.
3 Accessories
Designation
Short designation
Target plate PRA 54
Wall mount for the magnetic holder PMA 82
Magnetic holder PMA 83
Tripod PMA 20
4 Technical data
Right of technical changes reserved.
Range of the lines and intersection point 20 m (65 ft)
Accuracy
1
±3mmat10m(±0.12inat33ft)
Self-leveling time 3 s (typical)
Laser class Class 2, visible, 510 - 530 nm, ±10 nm (EN 60825-
1:2007 / IEC 60825 - 1:2007); class II (CFR 21 §1040
(FDA)
Line width Distance 5 m: < 2 mm
Self-leveling range ±4° (typical)
Automatic power-off Activated after: 1 h
Operating status indicator LED and laser beams
Power supply AA‑size batteries, Alkaline batteries: 4
Battery life Alkaline battery 2,500 mAh, Temperature +24°C
(+75 °F): 8 - 14 h (depending on the number of lines
switched on)
Operating temperature Min. -10°C / Max. +50°C (+14 to 122 °F)
Storage temperature Min. -25°C / Max. +63°C (-13 to 145 °F)
Dust and water spray protection (except battery com-
partment)
IP 54
in accordance with IEC 60529
Tripod thread (tool) UNC¹⁄₄"
Weight Including battery: 520 g (1.15 lbs)
Dimensions 65 x 107 x 95 mm (2 ¹/₂ x 4 ¹/₄ x 3 ³/₄ in)
1
Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810G).
en
12