3.
Select an access control device in the device list and click M1 Card Encrypon Vericaon to
enter the M1 Card Encrypon Vericaon page.
4.
Set the switch to on to enable the M1 card encrypon funcon.
5.
Se
t the sector ID.
Note
The sect
or ID ranges from 1 to 100.
By default, Sector 13 is encrypted. It is recommended to encrypt sector 13.
6.
Click Sa
ve to save the sengs.
Set RS-485 Parameters
You can set the access control device's RS-485 parameters including the baud rate, data bit, the
stop bit, parity type, ow control type, communicaon mode, work mode, and connecon mode.
Steps
Note
The RS-485 Sengs should be supported by the device.
1.
En
ter the Access Control module.
2.
On the navigaon bar on the le, enter Advanced Funcon → More Parameters .
3.
Select an access control device in the device list and click RS-485 to enter the RS-485 Sengs
page.
4.
Select the serial port number fr
om the drop-down list to set the RS-485 parameters.
5.
Set the serial number, external device, authencaon center, baud rate, data bit, stop bit, parity
type, ow control type, communicaon mode, and working mode in the drop-down list.
6.
Click Save.
The congured parameters will be applied to the device automacally.
When y
ou change the working mode or connecon mode, the device will reboot
automacally.
Set Wiegand Parameters
You can set the access control device's Wiegand channel and the communicaon mode. Aer
seng the Wiegand parameters, the device can connect to Wiegand card reader via Wiegand
communicaon.
Steps
Note
This funcon should be supported by the device.
1.
En
ter the Access Control module.