Aer enabling the Live Face Detecon funcon, the system will lock the user's face for 5
minutes if the live face detecon is failed for more than the congured aempts. The
same user cannot authencate via the fake face within 5 minutes. Within the 5 minutes,
the user can authencate via the real face twice connuously to unlock.
Liv
eness Level
Aer enabling Face An-Spoong funcon, you can set the matching security level when
perf
orming live face authencaon.
4.
Click OK.
5.
Oponal: Click Copy to, and then select the card reader(s) to copy the parameters in the page to
the selected card reader(s).
Congure Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
parameters.
Before You Start
Add access control device to the client, and make sure the device supports alarm output.
Steps
1.
Click Access Control → Advanced Funcon → Device Parameter to enter access control
parameter conguraon page.
2.
In the de
vice list on the le, click
to expand the door, select an alarm input and you can edit
the alarm input's par
ameters on the right.
3.
Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output Acve
Time
How long the alarm output will last aer triggered.
4.
Click OK.
5.
Oponal: Se
t the switch on the upper right corner to ON to trigger the alarm output.
9.7.2 Congure Remaining Open/Closed
You can set the status of the door as open or closed. For example, you can set the door remaining
closed in the holiday, and set the door remaining open in the specied period of the work day.
Before You Start
Add the access control devices to the system.
Steps
1.
Click Access Control → Advanced Funcon → R
emain Open/Closed to enter the Remain Open/
Closed page.