User's Manual

Table Of Contents
Select an authencaon mode according to your actual needs from the drop-down list.
Mulple People Authencaon
Mulple people can be authencated at the same me.
Recognion Interval
If the interval between card presenng of the same card is less than the congured value, the
card presenng is invalid.
Alarm of Max. Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Max. Authencaon Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Communicaon with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Max. Interval When Entering Password
When you entering the password on the card reader, if the interval between pressing two digits
is longer than the set value, the digits you pressed before will be cleared automacally.
OK LED Polarity/Error LED Polarity
Se
t OK LED Polarity/Error LED Polarity of the access control device according to the card reader
parameters. Generally, adopts the default sengs.
Enable Tampering Detecon
Enable the an-tamper detecon for the card reader.
Set Privacy Parameters
Set the event storage type, authencaon
sengs, picture upload and storage parameters, and
the picture clearing parameters.
Go to Conguraon → Gener
al → Privacy
Event Storage Sengs
Select a method to delete the event. You can select from Delete Old Events Periodically, Delete
Old Events by Specied Time, or
Overwring.
Delete Old Events Periodically
Drag the block or enter number to set the period for event deleng. All events will be deleted
according to the congured me duraon.
Delete Old Events by Specied Time
Set a me and all events will be deleted on the congured me.
Overwring
DS-K5671B Series Face Recognion Terminal User Manual