User's Manual

Table Of Contents
Note
If you set Communicaon Direcon as Sending, y
ou are required to set the Wiegand Mode as
Wiegand 26 or Wiegand 34.
6.
Check Enable Wieg
and to enable the Wiegand funcon.
7.
Click Save.
The congured parameters will be applied to the device automacally.
Aer changing the communicaon direcon, the device will reboot automacally.
Enable M1 Card Encrypon
M1 card encrypon can improve the security level of authencaon.
Steps
Note
The
funcon should be supported by the access control device and the card reader.
1.
En
ter the Access Control module.
2.
On the navigaon bar on the le, enter Advanced Funcon → More Parameters .
3.
Select an access control device in the device list and click M1 Card Encrypon Vericaon to
enter the M1 Card Encrypon
Vericaon page.
4.
Set the switch to on to enable the M1 card encrypon funcon.
5.
Set the sector ID.
Note
The sect
or ID ranges from 1 to 100.
By default, Sector 13 is encrypted. It is recommended to encrypt sector 13.
6.
Click Sa
ve to save the sengs.
9.8 Congure Linkage Acons for Access Control
You can congure dierent linkage acons for the event detected by the access control device.
Aer that, linkage
acons will be triggered once the event happens. This mechanism is used for
nofying the security personnel the event, or triggering automac access control in real me.
Two types of linkage acons are supported:
Client Acons: When the event is detected, it will trigger the acons on the client, such as the
client making an audible warning..
Device Acons: When the event is detected, it will trigger the acons of a specic device, such
as buzzing of a c
ard reader and, opening/closing of a door, ..
DS-K1T681 Series Face Recognion Terminal User Manual