User's Manual
8.5.18 Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate and output type.
Click Conguraon → Access Con
trol → RS-485 Sengs .
Click Save to save the sengs
aer the conguraon.
Peripheral Type
Select a peripheral from the drop-down list according the actual situaon. You can select from
Card Reader, Extension Module, Access Controller, or Disable.
Note
Aer the peripheral is changed and saved, the device will reboot automacally.
RS-485 Address
Se
t the RS-485 Address according to your actual needs.
Note
If you select Access Con
troller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud r
ate when the devices are communicang via the RS-485 protocol.
Output Type
If you select Access Controller as the peripheral type, you should set the parameter. The device
will output the card No. or the employee ID to the access controller.
8.5.19 Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
Note
Some device models do not support this funcon. Refer to the actual products when conguraon.
1. Click Conguraon → Access Con
trol → Wiegand Sengs .
DS-K1T680 Series Face
Recognion Terminal User Manual
77