The door remains open for the congured me duraon aer the rst person is authorized
unl the remain open duraon ends. If you select this mode, you should set the remain open
duraon.
Note
The remain open duraon should be between 0 and 1440 minutes. By default, the remain
open duraon is 10 minutes.
Disable Remaining Open aer First Person
Disable the funcon of rst person in, namely normal authencaon.
Note
You can authencate by the rst person again to disable the rst person mode.
4.
Click Add on the Fir
st Person List panel.
5.
Select person(s) in the le list and the person(s) will be add to the selected persons as the rst
person(s) of the doors.
The added rst person(s) will list in the First Person List
6.
Oponal: Select a rst person from the list and click Delete to remove the person from the rst
person list.
7.
Click Save.
10.7.8 Congure An-Passback
The
an-passback feature is designed to minimizes the misuse or fraudulent use of access
credenals such as passing back card to an unauthorized person, or tailed access. The an-
passback funcon establishes a specic sequence in which access credenals must be used in
order to grant access. You can set the sequence according to the actual path via the client and if
the person uses the credenal in wrong sequence, you can also reset the an-password records.
Be
fore You Start
Add access control device to the client, and enable the an-passing back funcon of the access
control device.
Steps
Note
Either the an-passing back or mul-door interlocking funcon can be congured for an access
c
ontrol device at the same me. For the conguraon of mul-door interlocking, refer to .
1.
Click Access Con
trol → Advanced Funcon An-Passback to enter the An-Passpack Sengs
page.
2.
Select an access control device on the le panel.
3.
Select a c
ard reader as the beginning of the path in the First Card Reader eld.