User's Manual

Table Of Contents
10.7.4 Congure Custom Wiegand Rule
Based on the knowledge of uploading rule for the third party Wiegand, you can set mulple
customized Wiegand rules to communicate between the device and the third party card readers.
Be
fore You Start
Wire the third party card readers to the device.
Steps
Note
B
y default, the device disables the custom wiegand funcon. If the device enables the custom
Wiegand funcon, all wiegand interfaces in the device will use the customized wiegand protocol.
Up to 5 custom Wiegands can be set.
For details about the custom Wiegand, see Custom Wiegand Rule Descripons.
1.
Click Access Con
trol → Advanced Funcon → Custom Wiegand to enter the Custom Wiegand
page.
2.
Select a custom Wiegand on the le.
3.
Create a Wiegand name.
Note
Up to 32 characters are allowed in the custom Wiegand name.
4.
Click Select De
vice to select the access control device for seng the custom wiegand.
5.
Set the parity mode according to the property of the third party card reader.
Note
Up t
o 80 bits are allowed in the total length.
The odd parity start bit, the odd parity length, the even parity start bit and the even parity
length range from 1 to 80 bit.
The start bit of the card ID, the manufacturer code, the site code, and the OEM should range
from 1 to 80 bit.
6.
Se
t output transformaon rule.
1) Click Set Rule to open the Set Output Transformaon Rules window.
DS-K6300 Series Payment Terminal User Manual