6. Tap OK to save the
sengs and go back to the Wi-Fi tab.
7. Tap to save the network parameters.
7.2.3 Set RS-485 Parameters
The face recognion terminal can connect external access controller, secure door control unit or
card reader via the RS-485 terminal.
Steps
1. Tap Comm.
(Communicaon Sengs) on the Home page to enter the Communicaon Sengs
page.
2. On the Communicaon Sengs page, tap RS-485 to enter the RS-485 tab.
Figure 7-6 Set RS-485 Parameters
3. Select an peripheral type according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4. Tap the back icon at the upper le corner and you should reboot the device if you change the
parameters.
DS-K1T643 Series Face Recognion Terminal User Manual