4. Optional: You can set the parameters of multiple areas by repeating the above steps.
II. Expert Mode
You can configure the motion detection parameters of day/night switch according to the actual needs.
Steps
1. Select expert mode in Configuration.
2. Set parameters of expert mode.
Day/Night Switch
OFF: Day/night switch is disabled.
Day/Night Auto-Switch: The system switches day/night mode automatically according to environment. It displays colored
image at day and black and white image at night.
Day/Night Scheduled-Switch: The system switches day/night mode according to the schedule. It switches to day mode during
the set periods and switches to night mode during the other periods.
Sensitivity
The higher the value of sensitivity is, the more sensitive the motion detection is. If the sensitivity is set to 0, motion detection
and dynamic analysis do not take effect.
3. Select an Area and click Draw Area. Click and drag the mouse on the live video, then release the mouse to finish drawing one area.
Figure 6-2 Set Rules
Stop Drawing
Finish drawing one area.
Clear All
Delete all the areas.
4. Optional: Repeat the above steps to set multiple areas.
When the configured area is covered and cannot be monitored normally, the alarm is triggered and the device takes certain alarm
response actions.
Steps
1. Go to Configuration Event Basic Event Video Tampering.
2. Select the channel number.
3. Check Enable.