II. Set Shield Region
The shield region allows you to set the specific region in which the face capture does not work. Steps:
1. Click to draw shield area by left click end-points in the live view window, and right click to finish the area drawing.
2.
Optional: Click to delete the drawn areas.
Note
You are allowed to draw up to 4 areas on the same image, and each area can be set with 3-10 points
3. Click Save.
III. Advanced Configuration
Face Capture Version: It lists the version of the algorithms library.
Upload Feature: Check to upload the feature of captured target.
Capture Times: Refers to the capture times a face will be captured during its stay in the configured area.
Quick Shot: You can define quick shot threshold and max. capture interval.
Quick Shot Threshold: It stands for the quality of face to trigger quick shot.
Max. Capture Interval: It describes the max. time occupation for one quick shot.
No Wearing Mask Linkage: Check Audible Warning, the device will output audio alarm if the target is not wearing mask.