User Manual

28
Body Thermography
Body Thermography function can detect temperature of human face or body in the scene, and output alarm if the temperature is
higher than the setting value.
Configure the parameters of body temperature measurement.
Before You Start
Go to Configuration System Maintenance VCA Resource Type, select Body Thermography.
Steps
1. Go to Configuration Temperature Measurement Basic Settings to configure parameters.
Enable Temperature Measurement
Check to enable temperature measurement function.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature information on the stream.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Add Original Data on Stream
Check to add original data on thermal view.
Data Refresh Interval
It means the refresh interval of temperature information.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Distance:
Set the distance between device and the target.
Emissivity
Set the emissivity of your target.
Note
Refer to the emissivity table for reference in the manual or online.
Version
View the version of current algorithm.
2. Click Save.