Sensitivity settings will also affect the anti-interference of the detector. It is not recommended to use a sensitivity that is too high for
the operation place.
In order to adjust the detection sensitivity, the test object should be placed in different positions on the body in different ways and
carried through the detector.
Steps:
1. Define the overall sensitivity, which can be adjusted manually(except for ankle height).
2. Define ankle height sensitivity (zone sensitivity). Manual ground sensitivity adjustment is available.
3. For different installation place, the amount and orientation of metal in the ground where the probe door is located may vary.
The required ground height sensitivity settings varies according to the place situation.
Set Zone Sensitivity
After adjusting the safety level, fix the key test item in the ankle position and carry the item through the detector. Walk through the
detector in at least two ways: A. Step one foot with the test item in the center of the detector. B. Step over the center of the detector
with one foot with the test item.