User Manual

Table Of Contents
UM IPC-4300H 040320NA 176
Diode
Range
Resolution
Function
2.0 V
1 mV
Schottky diode: 0.15 to 0.25 V
Rectifier diode: 0.6 to 1.0 V
Triode PN junction: 0.5 to 0.8 V
Capacitance
Range
Accuracy
Resolution
6.600 nF
± (0.5%+20)
1 pF
66.00 nF
± (3.5%+8)
10 pF
660.0 nF
100 pF
6.600 µF
1 nF
66.00 µF
10 nF
660.0 µF
± (5%+8)
100 nF
6.600 mF
1 µF
66.00 mF
10 µF
Optical Power Meter Specifications
Measurement Range (dBm)
-70 to 10
Wavelength (nm)
850, 1300, 1310, 1490, 1550,
1625
Detector
InGaAs
Uncertainty
< ±3% dB (-10 dBm, 22 °C)
< ±5% dB (full range, 22 °C)
Display Resolution
Linear: 0.1%
Nonlinear: 0.01 dBm
Operating Temperature (° C)
-10 to 50
Storage Temperature (° C)
-20 to 70
Connector Type
FC/PC