User Manual
ERT-F2xx DVR User Manual
UM ERT-F2xx 030118NA 85
3) Select the alarm linkage action(s) you want to disarm for local alarm input 1. The selected linkage
actions include the Full Screen Monitoring, Audible Warning, Notify Surveillance Center, Send Email,
and Trigger Alarm Output.
When the alarm input 1 (Local<-1) is enabled with one-key disarming, the other alarm input settings
are not configurable.
Select Trigger Channel tab and select one or more ch
annels to record or become full-screen monitoring
5.
when an external alarm is input, and click Apply to save the settings.
Select Arming Schedule to set the arming schedule of handling actions.
6.
Set Arming Schedule of Alarm Input
Figure 8-6
Choose a day of the week (a maximum of eight time periods can be set within each day), and click Apply to
7.
save the settings.
Time periods cannot repeat or overlap.
Repeat the above steps to set up arming schedule for other days of the week. You can also use the
Copy button to copy an arming schedule to other days.
Select Linkage Action to set up alarm response actions of the alarm input (please refer to Chapter 8.8
8.
Setting Alarm Response Actions).
If necessary, select PTZ Linking tab and set PTZ linkage of the alarm input.
9.
Set PTZ linking parameters and click OK to complete the settings of the alarm input.
10.