Panic Zone
The zone activates all the time. It is usually used in the sites equipped with panic button,
smoke detector and glass-break detector.
Keyswitch Zone
The linked area will arm after being triggered, and disarm after being restored. In the case of
the tampering alarm, the arming and disarming operation will not be triggered.
Note
Two trigger types (by trigger times and by zone status) can be selected for the zone. If the
zone status type is selected, set the trigger operation (trigger arming/disarming).
Disabled Zone
Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors.
24 Hours Zone
The zone activates all the time with sound/siren output when alarm occurs. It is usually used
in fire hazardous areas equipped with smoke detectors and temperature sensors.
6. Enable Cross zone, Silent Alarm, etc. according to your actual needs.
Note
Some zones do not support the function. Refer to the actual zone to set the function.
7. Set the Sounder Delay Time. The sounder will be triggered immediately or after the set time.
8. If required, link a camera for the zone.
9. Enable Detector Enrolled, enter the serial No., and set the linked camera No.
10. Click OK.
Note
After setting the zone, you can enter Status Zone to view the zone status.
11. Click Detector Settings to enter the Detector Settings page.