User Manual
34
The device will push notifications when panic alarm is triggered or restored by zones, keypads
or keyfobs.
Medical Alarm
The device will push notifications when medical alarm is triggered.
Gas Alarm
The device will push notifications when gas alarm is triggered.
Panel Status
The device will push notifications when the control panel system status is changed.
Zone Status
The device will push notifications when the zone status is changed.
Peripherals Status
The device will push notifications when any peripheral status is changed.
Panel Operation
The device will push notifications when the user operate the AX PRO.
Smart Alarm Notification
The device will push notifications when the alarm is triggered in thermal cameras.
Alarm Receiving Center (ARC)
You can set the alarm receiving center's parameters and all alarms will be sent to the configured
alarm center.
Steps
1. In the site, tap the AX PRO and then log in to the device (if required).
2. Tap → Communication Parameters→ Alarm Receiving Center (ARC) to enter the page.
3. Select an ARC and enable it.
4. Select the Protocol Type as ADM-CID, ISUP, SIA-DCS, *SIA-DCS, or *ADM-CID to set uploading
mode.
ADM-CID or SIA-DCS
You should select the Address Type as IP or Domain name, and enter the IP/domain name,
port number, account code, transmission mode, retry timeout period, attempts, polling
option and period test.
Note
Set the period test interval with the range from 10 seconds to 24 hours.
ISUP
You do not need to set the ISUP protocol parameters.
*SIA-DCS or *ADM-CID
You should select the Address Type as IP or Domain name, and enter the IP/domain name,