User Manual
7
9
Funcons
You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client.
While Any of the two inputs generates an alarm event, the contact reports the alarm to the AX PRO. The LED keeps blue for 2 s.
4
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Set Up with App
8
Funcon
Zone Type
Stay Arm Bypass
Chime
Enable Silent Zone
Slide to green to enable the chime.
Slide to green to make the zone keep
silent while alarm is triggered.
Select the zone type of the detector.
Descripon
You can view the device status including temperature, signal intensity,baery level, lid, magnec contact, external contact, etc.,on the device page.
Tap the buon to enter the sengs page.
Double Knock
Slide to green to make the zone alarm
with double knock.
Cross Zone
Link Camera
Magnec Contact
External Contact1
Slide to green to bypass the zone from stay arming.
If the alarm triggered in both of the linked zones within
the set me, two alarm messages will be reported.
LED
Turn On/Off the LED.
Polling Rate
Set the interval of heartbeat.
Signal Strength Test
Enter the test mode, and view the LED indicaon.
Detecon Zone Test
Enter the test mode, separate the contact, and start
the test with Magnet Detecon Performance Table.
Zone Bypass
By pass the zone.
Link with a camera for intruder verificaon.
Slide to green to enable magnec contact(Not allowed under EN).
Slide to green to enable the wired external contact 1.
External Contact2
Slide to green to enable the wired external contact 2.
Formang
1. Remove the baery.
2. Hold the TAMPER buon and power the detector on at the same me.
The red LED flashes 3 me when the formang is completed.
Disallowed field adjustable sengs: None