Operation Manual
Video Intercom Door Station·User Manual
51
3) (Optional) Enable the function of Delay Door Alarm.
4) Click the Save button to enable the settings.
Enabling Card Encrypt, the door station can recognize the encrypted information
of the card when you swiping the card on the door station.
Elevator Control
1) Select the elevator No., interface, RS485 protocol.
2) Select Yes/No of the elevator linkage.
3) Enter the server IP address and server port No..
3. Click the Save button to enable the settings.
IO Input and Output
Step:
1. Click the I/O Input and Output button to enter the I/O input and output interface.
Figure 8-27 IO Input/Output Configuration
2. Select I/O input No., input mode, output No., and output mode.
3. Click the Save button to enable the settings.
For door station (D series), there are 8 I/O Input Terminals. Terminal 1~4 correspond
to SENSOR interfaces (S1, S2, S3, S4) of door station. Terminal 5~8 correspond to
interfaces of ALARM IN (A1, A2, A3, A4). You can select an I/O input No. (S1, S2, S3, S4,
AI, A2, A3, A4) from the drop-down list and set the I/O input as door magnetic exit
button.
For door station (V series), there are 4 I/O Input Terminals, corresponding to SENSOR
interfaces (S1, S2, S3, S4) of door station.
For door station (D series and V series), there are 4 I/O Output Terminals.
Terminal 1~2 correspond to DOOR interfaces (NO1/COM1/NC1; NO2/COM2/NC2) of
door station. You can enable/disable IO Out by selecting from the dropdown list.
Terminal 3~4 correspond to interfaces of ALARM OUT (AO1+, AO1-; AO2+, AO2-).