User Manual

Table Of Contents
Figure 8-13 Door Parameters Sengs Page
Click Save to save the sengs aer the conguraon.
Door No.
Select the device corresponded door No.
Name
You can create a name for the door.
Open Duraon
Set the door unlocking duraon. If the door is not opened for the set me, the door will be
locked.
Door Open Timeout Alarm
An alarm will be triggered if the door has not been closed within the congured me duraon.
Door Contact
You can set the door contact as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Closed.
Exit
Buon Type
You can set the exit buon as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Open.
Door Lock Powering O
You can set the door lock status when the door lock is powering o. By default, it is Remain
Closed.
Extended Open
Duraon
The door contact can be enabled with appropriate delay aer person with extended access
needs swipes her/his card.
DS-K5671-3XF Series Face Recognion Terminal User Manual
82