User Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Quick Operation
- Chapter 7 Basic Operation
- Chapter 8 Operation via Web Browser
- 8.1 Login
- 8.2 Live View
- 8.3 Person Management
- 8.4 Search Event
- 8.5 Configuration
- 8.5.1 Set Local Parameters
- 8.5.2 View Device Information
- 8.5.3 Set Time
- 8.5.4 Set DST
- 8.5.5 View Open Source Software License
- 8.5.6 Upgrade and Maintenance
- 8.5.7 Log Query
- 8.5.8 Security Mode Settings
- 8.5.9 Certificate Management
- 8.5.10 Change Administrator's Password
- 8.5.11 View Device Arming/Disarming Information
- 8.5.12 Network Settings
- 8.5.13 Set Video and Audio Parameters
- 8.5.14 Customize Audio Content
- 8.5.15 Set Image Parameters
- 8.5.16 Set Supplement Light Brightness
- 8.5.17 Time and Attendance Settings
- 8.5.18 Set Video Intercom Parameters
- 8.5.19 Configure SIP Parameters
- 8.5.20 Access Control Settings
- 8.5.21 Set Biometric Parameters
- 8.5.22 Set Notice Publication
- 8.5.23 Temperature Measurement Settings
- Chapter 9 Client Software Configuration
- 9.1 Configuration Flow of Client Software
- 9.2 Device Management
- 9.3 Group Management
- 9.4 Person Management
- 9.5 Configure Schedule and Template
- 9.6 Set Access Group to Assign Access Authorization to Persons
- 9.7 Configure Advanced Functions
- 9.8 Door Control
- Appendix A. Tips When Collecting/Comparing Face Picture
- Appendix B. Tips for Installation Environment
- Appendix C. Dimension
Chapter 3 Installaon
3.1 Installaon Environment
• Avoid backlight, direct sunlight, and indirect sunlight.
• For beer face recognion, there should be light source in or near the installaon environment.
• Sunlight, wind, hot/cool air from air
condioner and other external factors, which may aect
surface temperature, will create the deviaon of the temperature measurement. In order to get
an accurate result, make sure the device is applied indoors and windlessly (where is relavely
isolated from the outdoors). The working temperature should keep between 10 °C and 35 °C. If
there are no suitable environments for temperature measurement (the area faces the indoor
and connects the outdoor, the area at the door of the indoor environment, etc.), building a
temporary temperature measurement environment is suggested.
•
Inuence Factors of Temperature Measurement:
Wind: The wind will take the heat away, which may aect the measurement result.
Sweat: The sweat will take the heat away, which may
aect the measurement result.
Air Condioner (Cool Air): If the indoor temperature is low, the surface temperature may also
lower than the actual temperature, which may aect the measurement result.
Air Condioner (Heat) or Heang: If the indoor temperature is high, the surface temperature
may also higher than the actual temperature, which may
aect the measurement result.
• In order to make the device work properly, you should wait for 90 min aer the device is
powered on.
• For details about
installaon environment, see Tips for Installaon Environment .
3.2 Mount With Bracket
3.2.1 Preparaon before Mounng with Bracket
Make sure you have drilled holes on the turnsle. If not, follow the steps below to drill holes.
Steps
1. Use 4 screws (M3 or M4), secured by ange nuts, to install the reinforcing board on the inner
surface of the
turnsle.
Note
The distance between the turnsle and the edge should be no longer than 10 mm.
2. Drill holes on the turnsle's inner surface according to the gure displayed below. And install
water-proof nut.
DS-K5671-3XF Series Face Recognion Terminal User Manual
4