Table 8-1 Temperature Measurement Parameters Descripons
Parameter Descripon
Temperature Measurement
Only
When enabling the funcon, the device will not authencate
the permissions, but only take the temperature. When
disabling the funcon, the device will authencate the
permissions and at the same
me take the temperature.
Note
Aer enabling Temperature Measurement Only, you can
enable Capture White Light Picture. Aer enabling Capture
White Light Picture, the picture will be captured when
authencang.
Unit Select a temperature unit according to your preference.
Over-Temperature Threshold
(Max./Min.)
Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured
parameters, an alarm will be triggered. By default, the value is
37.3°.
Temperature Compensaon If the measured temperature is higher/lower than the actual
object's temperature, you can set the compensaon
temperature here. Available range: -99 °C to 99 °C
Door Not Open When
Temperature is Abnormal
When enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the funcon is enabled.
4. Click Save.
Black Body
Sengs
The black body can correct the measuring temperature. You should set the black body parameters
if the black body temperature measurement scene is required. If no black body is required, do not
set the black body parameters, or the temperature may not correct.
Steps
1. Click
Conguraon → Temperature → Black Body Sengs .
DS-K5671-3XF Series Face Recognion Terminal User Manual