Chapter 3 Installaon
3.1 Installaon Environment
Avoid backlight, direct sunlight, and indirect sunlight.
For beer face recognion, there should be light source in or near the installaon environment.
Sunlight, wind, hot/cool air from air
condioner and other external factors, which may aect
surface temperature, will create the deviaon of the temperature measurement. In order to get
an accurate result, make sure the device is applied indoors and windlessly (where is relavely
isolated from the outdoors). The working temperature should keep between 10 °C and 35 °C. If
there are no suitable environments for temperature measurement (the area faces the indoor
and connects the outdoor, the area at the door of the indoor environment, etc.), building a
temporary temperature measurement environment is suggested.
Inuence Factors of Temperature Measurement:
Wind: The wind will take the heat away, which may aect the measurement result.
Sweat: The sweat will take the heat away, which may
aect the measurement result.
Air Condioner (Cool Air): If the indoor temperature is low, the surface temperature may also
lower than the actual temperature, which may aect the measurement result.
Air Condioner (Heat) or Heang: If the indoor temperature is high, the surface temperature
may also higher than the actual temperature, which may
aect the measurement result.
In order to make the device work properly, you should wait for 90 min aer the device is
powered on.
For details about
installaon environment, see Tips for Installaon Environment .
3.2 Install Device
Before You Start
Make sure the ground surface has drilled holes for device
installaon.
Steps
1. Remove the two
boom screws (2-SC-KM3×5B-JMF) on both sides of the boom cover.
2. Remove the boom cover.
3. Align the device with the drilled holes on the ground and insert 3 supplied expansion bolts
(M6×65). Make sure the expansion bolts are higher than the ground.
4. Secure the expansion bolts with nuts.
5. Align the device with the
mounng plate and hang the device on the mounng plate.
6. Install the
boom cover back on the device with 2 boom screws.
DS-K5604A-3XF Series Face Recognion Terminal User Manual