User Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Basic Operation
- 6.1 Set Application Mode
- 6.2 Login
- 6.3 Communication Settings
- 6.4 User Management
- 6.5 Temperature Measurement
- 6.6 Import and Export Data
- 6.7 Identity Authentication
- 6.8 System Settings
- 6.9 Set Access Control Parameters
- 6.10 Maintenance
- 6.11 Time and Attendance Status Settings
- 6.12 View System Information
- 6.13 Video Intercom
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.4.1 Add Organization
- 7.4.2 Configure Basic Information
- 7.4.3 Issue a Card by Local Mode
- 7.4.4 Upload a Face Photo from Local PC
- 7.4.5 Take a Photo via Client
- 7.4.6 Collect Face via Access Control Device
- 7.4.7 Configure Access Control Information
- 7.4.8 Customize Person Information
- 7.4.9 Configure Resident Information
- 7.4.10 Configure Additional Information
- 7.4.11 Import and Export Person Identify Information
- 7.4.12 Import Person Information
- 7.4.13 Import Person Pictures
- 7.4.14 Export Person Information
- 7.4.15 Export Person Pictures
- 7.4.16 Get Person Information from Access Control Device
- 7.4.17 Move Persons to Another Organization
- 7.4.18 Issue Cards to Persons in Batch
- 7.4.19 Report Card Loss
- 7.4.20 Set Card Issuing Parameters
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.7.1 Configure Device Parameters
- 7.7.2 Configure Remaining Open/Closed
- 7.7.3 Configure Multi-Factor Authentication
- 7.7.4 Configure Card Reader Authentication Mode and Schedule
- 7.7.5 Configure First Person In
- 7.7.6 Configure Anti-Passback
- 7.7.7 Configure Device Parameters
- 7.8 Configure Linkage Actions for Access Control
- 7.9 Door Control
- 7.10 Event Center
- 7.11 Time and Attendance
- 7.12 Remote Configuration (Web)
- 7.12.1 View Device Information
- 7.12.2 Change Device Password
- 7.12.3 Time Management
- 7.12.4 System Maintenance
- 7.12.5 Configure RS-485 Parameters
- 7.12.6 Security Mode Settings
- 7.12.7 Network Parameters Settings
- 7.12.8 Report Strategy Settings
- 7.12.9 Network Center Parameters Settings
- 7.12.10 Configure SIP Parameters
- 7.12.11 Set Relay Parameters
- 7.12.12 Set Access Control Parameters
- 7.12.13 Set Face Recognition Terminal Parameters
- 7.12.14 Configure Face Picture Parameters
- 7.12.15 Configure Supplement Light Parameters
- 7.12.16 Set Device No.
- 7.12.17 Configure Video and Audio Parameters
- 7.12.18 Configure Volume Input or Output
- 7.12.19 Operate Relay
- 7.12.20 View Relay Status
- Appendix A. Tips When Collecting/Comparing Face Picture
- Appendix B. Tips for Installation Environment
- Appendix C. Dimension
Chapter 3 Installaon
3.1 Installaon Environment
• Avoid backlight, direct sunlight, and indirect sunlight.
• For beer face recognion, there should be light source in or near the installaon environment.
• Sunlight, wind, hot/cool air from air
condioner and other external factors, which may aect
surface temperature, will create the deviaon of the temperature measurement. In order to get
an accurate result, make sure the device is applied indoors and windlessly (where is relavely
isolated from the outdoors). The working temperature should keep between 10 °C and 35 °C. If
there are no suitable environments for temperature measurement (the area faces the indoor
and connects the outdoor, the area at the door of the indoor environment, etc.), building a
temporary temperature measurement environment is suggested.
•
Inuence Factors of Temperature Measurement:
Wind: The wind will take the heat away, which may aect the measurement result.
Sweat: The sweat will take the heat away, which may
aect the measurement result.
Air Condioner (Cool Air): If the indoor temperature is low, the surface temperature may also
lower than the actual temperature, which may aect the measurement result.
Air Condioner (Heat) or Heang: If the indoor temperature is high, the surface temperature
may also higher than the actual temperature, which may
aect the measurement result.
• In order to make the device work properly, you should wait for 90 min aer the device is
powered on.
• For details about
installaon environment, see Tips for Installaon Environment .
3.2 Install Device
Before You Start
Make sure the ground surface has drilled holes for device
installaon.
Steps
1. Remove the two
boom screws (2-SC-KM3×5B-JMF) on both sides of the boom cover.
2. Remove the boom cover.
3. Align the device with the drilled holes on the ground and insert 3 supplied expansion bolts
(M6×65). Make sure the expansion bolts are higher than the ground.
4. Secure the expansion bolts with nuts.
5. Align the device with the
mounng plate and hang the device on the mounng plate.
6. Install the
boom cover back on the device with 2 boom screws.
DS-K5604A-3XF Series Face Recognion Terminal User Manual
3