User Manual

Table Of Contents
Parameter Descripon
disabling the device, the device will authencate the
permissions only.
Over-Temperature Alarm
Threshold(Max./Min.)
Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured parameters,
an alarm will be triggered. By default, the value is 37.3°.
Door Not Open When
Temperature is Abnormal
When Enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the temperature is enabled.
Temperature Measurement
Only
When enabling the funcon, the device will not authencate the
permissions, but only take the temperature. When disabling the
funcon, the device will authencate the permissions and at the
same
me take the temperature.
Measurement Area
Calibraon/Measure Area
Sengs
Congure the temperature measurement area and the
correcon parameters.
Black Body Sengs When enabling the funcon, you can congure the black body’s
parameters, including the distance, temperature, and emissivity.
6.6 Import and Export Data
On the Transfer page, you can export the event, the user data, the user picture, and the captured
picture to the USB ash drive. You can also import the user data and the user picture from the USB
ash drive.
6.6.1 Export Data
Steps
1. Tap Transfer on the Home page to enter the Transfer page.
2. On the Transfer page, tap Export Event, Export User Data, Export Prole Photo, and export
captured picture.
3. Tap Yes on the pop-up page and the data will be exported from the device to the USB
ash
drive.
Note
The supported USB
ash drive format is DB.
The system supports the USB ash drive with the storage of 1G to 32G. Make sure the free
space of the USB ash drive is more than 512M.
The exported user data is a DB
le, which cannot be edited.
Face Recognion Terminal User Manual