User Manual

Table Of Contents
Aer enabling the funcon, you can set the center's address type, IP address/domain name, port
No., EHome user name, etc.
Click Save.
7.12.10 Congure SIP Parameters
Set the master staon's IP address and the SIP server's IP address. Aer seng the parameters,
you can communicate among the access control device, door staon, indoor staon, master
staon, and the plaorm.
Note
Only the access control device and other devices or systems (such as door staon, indoor staon,
master staon, plaorm) are in the same IP segment, the two-way audio can be performed.
Click Maintenance and Management → Device to enter the device list.
Click
to enter the remote conguraon page.
Click Network → Linked Network Conguraon and set the master staon's IP address and SIP
server's IP address.
Click Save.
7.12.11 Set Relay Parameters
Click Maintenance and Management → Device to enter the device list.
Click to enter the remote conguraon page.
Click Alarm → Relay . Select a relay and click and set the relay name and output delay me.
Click OK to save the sengs.
7.12.12 Set Access Control Parameters
Steps
1. On the Device for Management page, click → Others → Access Control Parameters to enter
the Access Control Parameters tab.
2. Check the checkbox to enable the
funcon.
Voice Prompt
If you enable this funcon, the voice prompt is enabled in the device. You can hear the voice
prompt when
operang in the device.
Upload Pictures aer Capturing
If you enable this funcon, the captured pictures will be sent to the client soware.
Save Captured Pictures
Face Recognion Terminal User Manual