User Manual
Table Of Contents
- Legal Information
- Available Model
- Regulatory Information
- Safety Instruction
- Chapter 1 Preventive and Cautionary Tips
- Chapter 2 Product Description
- Chapter 3 Main Board Description
- Chapter 4 Terminal Description
- Chapter 5 Terminal Wiring
- Chapter 6 Settings
- Chapter 7 Activation
- Chapter 8 Client Software Configuration
- 8.1 Operation on Client Software
- 8.1.1 Add Device
- 8.1.2 Select Application Scenario
- 8.1.3 Configure Other Parameters
- 8.1.4 Manage Organization
- 8.1.5 Manage Person Information
- 8.1.6 Configure Schedule and Template
- 8.1.7 Manage Permission
- 8.1.8 Configure Advanced Functions
- Configure Access Control Parameters
- Configure Individual Authentication
- Configure Card Reader Authentication Mode and Schedule
- Configure Multiple Authentication
- Configure Opening Door with First Card
- Configure Anti-Passback
- Configure Cross-Controller Anti-passing Back
- Configure Multi-door Interlocking
- Configure Authentication Password
- Configure Custom Wiegand Rule
- 8.1.9 Search Access Control Event
- 8.1.10 Configure Access Control Alarm Linkage
- 8.1.11 Manage Access Control Point Status
- 8.1.12 Control Door during Live View
- 8.1.13 Display Access Control Point on E-map
- 8.2 Remote Configuration (Web)
- 8.3 Time and Attendance
- 8.1 Operation on Client Software
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch Description
- Appendix C. Custom Wiegand Rule Descriptions
If you set 0 as the adding mode, this eld is not required; if you set 2 as the adding mode,
input the device ID registered on the IP Server; if you set 3 as the adding mode, input the
device domain name registered on HiDDNS server; if you set 4 as the adding mode, input the
EHome account; if you set 6 as the adding mode, input the device serial No.
User Name
Input the device user name. By default, the user name is admin.
Password
Input the device password.
Cauon
The password strength of the device can be automacally checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at
least three kinds of following categories: upper case leers, lower case leers, numbers, and
special characters) in order to increase the security of your product. And we recommend you
reset your password regularly, especially in the high security system, reseng the password
monthly or weekly can
beer protect your product.
Proper conguraon of all passwords and other security sengs is the responsibility of the
installer and/or end-user.
Add Oine Device
You can input 1 to enable adding the
oine device, and then the soware will automacally
connect it when the oine device comes online. 0 indicates disabling this funcon.
Export to Group
You can input 1 to create a group by the device name (nickname). All the channels of the
device will be imported to the corresponding group by default. 0 indicates disabling this
funcon.
Channel Number
If you set 1 for Add Oine Device, input the channel number of the device. If you set 0 for Add
Oine Device, this eld is not required.
Alarm Input Number
If you set 1 for Add Oine Device, input the alarm input number of the device. If you set 0 for
Add Oine Device, this eld is not required.
Serial Port No.
If you set 5 as the adding mode, input the serial port No. for the access control device.
Baud Rate
If you set 5 as the adding mode, input the baud rate of the access control device.