User Manual
Table Of Contents
- Legal Information
- Available Model
- Regulatory Information
- Safety Instruction
- Chapter 1 Preventive and Cautionary Tips
- Chapter 2 Product Description
- Chapter 3 Main Board Description
- Chapter 4 Terminal Description
- Chapter 5 Terminal Wiring
- Chapter 6 Settings
- Chapter 7 Activation
- Chapter 8 Client Software Configuration
- 8.1 Operation on Client Software
- 8.1.1 Add Device
- 8.1.2 Select Application Scenario
- 8.1.3 Configure Other Parameters
- 8.1.4 Manage Organization
- 8.1.5 Manage Person Information
- 8.1.6 Configure Schedule and Template
- 8.1.7 Manage Permission
- 8.1.8 Configure Advanced Functions
- Configure Access Control Parameters
- Configure Individual Authentication
- Configure Card Reader Authentication Mode and Schedule
- Configure Multiple Authentication
- Configure Opening Door with First Card
- Configure Anti-Passback
- Configure Cross-Controller Anti-passing Back
- Configure Multi-door Interlocking
- Configure Authentication Password
- Configure Custom Wiegand Rule
- 8.1.9 Search Access Control Event
- 8.1.10 Configure Access Control Alarm Linkage
- 8.1.11 Manage Access Control Point Status
- 8.1.12 Control Door during Live View
- 8.1.13 Display Access Control Point on E-map
- 8.2 Remote Configuration (Web)
- 8.3 Time and Attendance
- 8.1 Operation on Client Software
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch Description
- Appendix C. Custom Wiegand Rule Descriptions
7.
Oponal: Check Export to Group to create a group by the device name.
8. Oponal: Add the oine devices.
1) Check Add Oine Device.
2) Input the required informaon, including the device channel number and alarm input
number.
3) Click Add.
Note
When the oine device comes online, the soware will connect it automacally.
9. Click Add to add the device.
Import Devices in a Batch
The devices can be added to the soware in batch by inpung the device informaon in the pre-
dened CSV le.
Perform this task to import devices in a batch.
Steps
1. Enter the Device Management page
2. Click Device → Hikvision Device → Add to open the adding device window.
3. Select Batch Import as the adding mode.
4. Click Export Template and then save the
pre-dened template (CSV le) on your PC.
5. Open the exported template
le and input the required informaon of the devices to be added
on the corresponding column.
Adding Mode
You can input 0, 2, 3, 4, 5, or 6 which indicated
dierent adding modes. 0 indicates that the
device is added by IP address or domain name; 2 indicates that the device is added via IP
server; 3 indicates that the device is added via HiDDNS; 4 indicates that the device is added via
EHome protocol; 5 indicates that the device is added by serial port; 6 indicates that the device
is added via Cloud P2P.
Address
Edit the address of the device. If you set 0 as the adding mode, you should input the IP
address or domain name of the device; if you set 2 as the adding mode, you should input the
IP address of the PC that installs the IP Server; if you set 3 as the adding mode, you should
input www.hik-online.com.
Port
Input the device port No. The default value is 8000.
Device
Informaon
Access Controller User Manual
48