Parameter Descripon
Note
Aer enabling Temperature Measurement Only, you can
enable Capture White Light Picture. Aer enabling Capture
White Light Picture, the picture will be captured when
authencang.
Unit Select a temperature unit according to your preference.
Over-Temperature Threshold
(Max./Min.)
Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured
parameters, an alarm will be triggered. By default, the value is
37.3°.
Temperature Compensaon If the measured temperature is higher/lower than the actual
object's temperature, you can set the compensaon
temperature here. Available range: -99 °C to 99 °C
Door Not Open When
Temperature is Abnormal
When enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the funcon is enabled.
4. Click Save.