Table 6-1 Temperature Measurement Parameters Descripons
Parameter Descripon
Enable Temperature Detecon When enabling the funcon, the device will authencate the
permissions and at the same me take the temperature. When
disabling the device, the device will authencate the
permissions only.
Over-Temperature
Thr
eshold(Max./Min.)
Edit the threshold according to actual situaon. If the detected
temperature is higher or lower than the congured parameters,
an alarm will be triggered. By default, the value is 37.3°.
Temperature Compensaon If the measured temperature is higher/lower than the actual
object's temperature, you can set the compensaon
temperature here. Available range: -99 °C to 99 °C
Door Not Open If Temp. is
Abnormal
When enabling the funcon, the door will not open when the
detected temperature is higher or lower than the congured
temperature threshold. By default, the funcon is enabled.
Temperature Measurement
Only
When enabling the funcon, the device will not authencate the
permissions, but only take the temperature. When disabling the
funcon, the device will authencate the permissions and at the
same me take the temperature.
Unit Select a temperature unit according to your preference.
Measurement Area
Calibraon/Measure Area
Sengs
Congure the temperature measurement area and the
correcon parameters.
6.6
Identy Authencaon
Aer network conguraon, system parameters conguraon and user conguraon, you can go
back to the inial page for identy authencaon. The system will authencate person according
to the congured authencaon mode.
Y
ou can authencate identy via 1:1 matching or 1:N matching.
1:N Matching
Compare the captured face picture with all face pictures stored in the device.
1: 1 Matching
Compare the captured face picture with the face pictures linked person informaon in the
device.