Up to 32 characters are allowed in the custom Wiegand name.
4. Click Select De
vice to select the access control device for seng the custom wiegand.
5. Set the parity mode according to the property of the third party card reader.
Note
Up to 80 bits are allowed in the total length.
The odd parity start bit, the odd parity length, the even parity start bit and the even parity
length range from 1 to 80 bit.
The start bit of the card ID, the manufacturer code, the site code, and the OEM should range
from 1 to 80 bit.
6. Se
t output transformaon rule.
1) Click Set Rule to open the Set Output Transformaon Rules window.
Figure 7-7 Set Output Transformaon Rule
2) Select rules on the le list.
The select
ed rules will be added to the right list.
3) Oponal: Drag the rules to change the rule order.
4) Click OK.
5) In the Custom Wiegand tab, set the rule's start bit, length, and the decimal digit.
7. Click Save.