User Manual
UM DS-90xxHUHI-F8/N User Manual 041717NA 93
Figure 145, Set Arming Schedule of Video Quality Diagnostics
9. Select Linkage Action tab to set alarm response actions of video quality diagnostics alarm.
10. Repeat the above steps to set arming schedule for other days of the week. You can also use the Copy
button to copy an arming schedule to other days.
11. Click the OK button to complete the channel’s video quality diagnostics settings.
12. Click the Apply button to save and activate settings.
13. (Optional) copy the same settings to other cameras by clicking the Copy button.
15.6. H
andling Exceptions
Exception settings refer to the handling method of various exceptions:
• HDD Full: The HDD is full
• HDD Error: Writing HDD error, unformatted HDD, etc.
• Network Disconnected: Disconnected network cable
• IP Conflicted: Duplicated IP address
• Illegal Login: Incorrect user ID or password
• Input/Recording Resolution Mismatch: The input resolution is smaller than the recording resolution
• Record/Capture Exception: No space for saving recorded files or captured pictures
1. Enter Exceptions interface, Menu > Configuration > Exceptions.
2. Handle the various exceptions as appropriate.