User Manual
UM DS-90xxHUHI-F8/N User Manual 041717NA 104
NOTE: The Server Port should be set in the range of 2000-65535 and is used
for remote client software access. The HTTP port is used for remote
IE access.
• Output Bandwidth Limit: You can check the checkbox to enable output bandwidth limit.
• Output Bandwidth: After enabling the output bandwidth limit, input the output bandwidth
in the text field.
NOTE: The output bandwidth limit is used for remote Live View and playback.
The minimum output bandwidth is 2 Mbps.
4. Click the Apply button to save and exit the interfac
e.
16.2.9. Configuring HTTPS Port
HTTPS provides authentication of the Web site and associated Web server that one is
communicating with, which protects against man-in-the-middle attacks. Perform the following steps
to set the https port number.
Example: If you set the port number to 443 and the IP address is 192.0.0.64,
you may access the device by inputting https://192.0.0.64:443 via the
Web browser.
NOTE: The HTTPS port can be configured only through the Web browser.
1. Open Web browser, input the IP address of device, and the Web server will select the
language automatically according to the system language and maximize the Web browser.
2. Input the correct user name and password, and click the Login button to log in to the device.
3. Enter the HTTPS settings interface, Configuration > Re
mote Configuration > Network
Settings > HTTPS
4. Create the self-signed certificate or authorized certificate.
Figure 159, HTTPS Settings
• OPTION 1: Create the self-signed certificate.
1) Click the Create button to create the following dial
og box.